Zodiac
AquaPure
®
3.5
split Return Plumbing instructions:
For Infloor Cleaning Systems
If the chlorinator is used with an in-floor cleaning
system, it must be installed in a separate dedicated
return line or damage to the chlorinator will occur.
nOTE Do not install the chlorinator on in-floor systems that
do not have a dedicated pool return as shown in
Figure 22.
Cell
The cell must be
installed as the last
piece of equipment in
the dedicated return
plumbing just before
the pool.
Pool
Return
Figure 22. new Pool Plumbing for in-Floor systems
3.6
Alternative Installation (When Pipe is
Obstructed)
If the only suitable length of pipe is obstructed, such as
on a multiport valve often found on a sand filter, it is
acceptable to 'lean' the cell over, up to a maximum of
45 degrees (see Figure 23). Mark the feeder holes in the
same angle that the cell will be leaning to ensure that
you drill in the right position.
45
Figure 23. Example of Alternative installation
|
Ei Series APURE35PLGC
Installation and Operation Manual
®
Pod
From
Pump
To In Floor
Cleaning
System
Do not install
.
past 45 degrees
Do not install past 45 degrees
English
3.7
Connection to an Aqualink
Control System or PDA (Optional)
WARning
FOR YOuR sAFETY: This procedure must be
performed by a professional pool/spa service
technician as described on the front cover of
this manual. The procedures in this manual must
be followed exactly. Failure to follow warning notices
and instructions may result in property damage,
serious injury, or death. Improper installation and/or
operation will void the warranty.
When using electrical products, basic precautions
should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK WHICH
CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation or service, ensure
that all power to the device is disconnected/
turned off at the circuit breaker. Connect only
to a circuit protected by a ground-fault circuit-
interrupter (GFCI).
• Grounding is required. The unit should be
serviced by a qualified service representative
and should be properly grounded and bonded.
• Install to permit access for servicing.
• Please read all cautions and safety instructions in
the Important Safety Instructions section. Before
attempting any electrical wiring, be sure to
read and follow safety instructions. Wiring
should only be attempted by a qualified
professional.
The AquaLink RS or PDA is a multi-function pool
controller which can fully control the function of
the Zodiac AquaPure Ei Series APURE35PLGC
chlorine generating device. Adjustment of the chlorine
production rate can be controlled from the main menu
of the AquaLink RS or PDA. The AquaLink RS or
PDA offers individual pool and spa settings for output
percentage. Refer to the AquaLink RS or PDA Owner's
Manual for more information.
nOTE The Zodiac AquaPure Ei Series APURE35PLGC
chlorine generating device will communicate with all
AquaLink models Rev. K or later.
3.7.1
Verify the Controller Type on the Power
Pack is set Correctly
Before wiring to an AquaLink RS Control System,
the controller type must be set to JANDY L/M to
allow communication between the power pack and the
AquaLink RS Control System. The default controller
setting on the power pack is JANDY L/M. Follow the
instructions below to verify the controller type is set
correctly.