SANITIZING PROCEDURE

Step 9
Mix a solution of sanitizer and
lukewarm water.
Solution
Water
Type
Sanitizer
3 gal. (12 L)
Step 10 Use 1/2 of the sanitizer/
water solution to sanitize all removed
components. Use a spray bottle to liberally
apply the solution to all surfaces of the
removed parts or soak the removed parts
in the sanitizer/water solution. Do not rinse
parts after sanitizing.
Step 11 Use 1/2 of the sanitizer/water
solution to sanitize all foodzone surfaces
of the ice machine and bin (or dispenser).
Use a spray bottle to liberally apply the
solution. When sanitizing, pay particular
attention to the following areas:
• Evaporator plastic parts - including top,
bottom and sides
• Ice machine base (top of bin) and area
above the water trough
• Bin sides and bottom
Do not rinse the sanitized areas.
32
Step 12 Replace all removed components.
Step 13 Wait 20 minutes.
Step 14 Reapply power to the ice machine
and place the toggle switch in the CLEAN
Mixed with
position.
2 oz (60 ml)
Step 15 Wait until the water trough refills,
sanitizer
then add the proper amount of Manitowoc
Ice Machine Sanitizer to the water trough.
Step 16 After the sanitize cycle is
complete (approximately 24 minutes) move
the toggle switch to the ICE position to start
ice making.
Model
K0300 K0400 K0420
K0500 K0700 K1000
K1700
Part Number: 000014142 Rev 02 5/17
Section 4
Amount of Sanitizer
3 ounces (90 ml)
6 ounces (180 ml)