GROUD FAULT CIRCUIT ITERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI)
protection is a system that shuts down the
electric circuit (opens it) when it senses an
unexpected loss of power, presumably to
ground. GFCI/GFI circuit protection is not
recommended with our equipment. If code
requires the use of a GFCI/GFI, then you
must follow the local code. The circuit must
be dedicated, sized properly and there
must be a panel GFCI/GFI breaker. We do
not recommend GFCI/GFI outlets as they
are known for more intermittent nuisance
trips than panel breakers.
MIIMUM POWER CORD
SPECIFICATIOS
Minimum
Maximum
Breaker Size
15 amp
14 gauge
20 amp
12 gauge
30 amp
10 gauge
40 amp
8 gauge
If a power cord is used, the wire size to the
receptacle is dependent upon location,
materials used, length of run, etc., so
it must be determined by a qualified
electrician. Local, state or national
requirements will supersede our minimum
requirements.
14
Maximum
Wire
Length of
Size
Power Cord
6 feet (1.83 m)
6 feet (1.83 m)
6 feet (1.83 m)
6 feet (1.83 m)
For United Kingdom Only
As the colors of the wires in the mains
lead of the appliance may not correspond
with the colored markings identifying the
terminals in your plug, proceed as follows:
• The wire which is colored green and
yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth ground
symbol
or colored green or green
and yellow.
• The wire colored blue must be
connected to the terminal which is
marked with the letter N or colored
black.
• The wire colored brown must be
connected to the terminal which is
marked with the letter L or colored red.
Part Number: 000014142 Rev 02 5/17