Description
Th e DC 5800a is an electric powered vacuum extractor
for use with source extraction, cleaning and material
transportation applications in most types of industries.
Th e extraction system functions with negative pressure
(vacuum) that draws the air through suction casings,
nozzles, hose systems, separator and fi lter systems. Coarse
separation of dust occurs in the unit's cyclone which is a
When emptying the container, it is unclipped
and removed away from the machine. After
that has be done the sack can be taken out of
the container.
Operation
Connect the machine to a suitable power source by fol-
lowing the specifi cations found on the serial number plate
on the machine. If an extension cord is to be used with the
unit, it should be suitably rated according to the prevailing
electrical code. Check rotation of the motor at startup. On
machines equipped with a phase reverser, incorrect rotation
can be easily changed. Machines not equipped with a phase
reverser will require the service of a qualifi ed electrician to
interchange two phases in the power supply.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running, or if the machine is equipped with a fi lter
monitor, when this is in the red area.
2010-12-16
highly effi cient separator for larger particulate. Th e fi ne
dust is separated and contained by the unit's fi lter system.
Separated material is collected for disposal in the plastic
sack or container at the base of the cyclone.
Filter cleaning with reverse pulse gives long fi lter life and
constant capacity.
The container is attached to the machine by
two fasteners.
For fi lter cleaning:
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
5.
If the fi lter condition meter reads green work can con-
tinue, if in the red, pulse clean again. If after several
repetitions, the fi lter condition still shows red the main
fi lter must be changed.
Th e container under the cyclone should be emptied when
it is fi lled to ca 2/3.
DC 5800a 5 kW - 9
Part No 9481