Displaying And Deleting Measurements - Beurer medical BM 85 Mode D'emploi

Masquer les pouces Voir aussi pour BM 85:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
spot and remain there calmly; close your eyes, breathe deeply
and evenly and try to relax.
If the next measurement also shows insufficient stability, you
can repeat the measurement after another resting period. If the
measurements continue to show some instability, identify the-
se blood pressure measurements as having been taken when
the circulatory system had not been sufficiently rested.
In this case, nervousness or inner anxiety may be the cau-
se and this cannot be cured by brief periods of rest. Existing
cardiac arrhythmias may also prevent a stable blood pressure
measurement.
A lack of resting blood pressure can have various causes,
such as physical or mental strain or distraction, speaking or
experiencing cardiac arrhythmias during the blood pressure
measurement.
In an overwhelming number of cases, the HSD diagnosis will
give a very good guide as to whether the circulatory system
is rested when taking the measurement. Certain patients
suffering from cardiac arrhythmia or chronic mental condi-
tions can remain haemodynamically unstable in the long-term,
something which persists even after repeated periods of rest.
The accuracy of the resting blood pressure results is redu-
ced in these users. Like any medical measurement method,
the precision of the HSD diagnosis is limited and can lead to
incorrect results in some cases. The blood pressure measure-
ments taken when the circulatory system was at rest represent
particularly reliable results.

7. Displaying and deleting measurements

The results of every successful measurement are stored
together with the date and time. The oldest measurement
is overwritten in the event of more than 60 measure-
ments.
• To access memory recall mode, the blood pressure
monitor must first be started. To do this press the
START/STOP button
• Within 3 seconds of the full-screen display appearing,
select the desired user memory (
M2 memory button.
– To view the measurements for user memory
the M1 memory button.
– To view the measurements for user memo-
ry
, press the M2 memory button.
Your last measurement will appear on the
display.
If Bluetooth
is activated (the
®
appears on the display), measurements are
automatically transferred.
Press the M1/M2 button to cancel data
transfer. The device will show average
values. The
symbol is no longer shown.
Press the M1 memory button if you have selected
user memory 1.
Press the M2 memory button if you have selected
user memory 2.
29
.
) with the M1 or
, press
symbol

Publicité

Table des Matières
loading

Table des Matières