Restoring The Factory Defaults - Abus CASA10010 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

In the main menu, select menu item 6 with SELECT and confirm by
pressing SET. A double tone sounds and the LEDs indicate the
output groups. LED 1 is used for output group 1 and LED 2 for
output group 2. You can switch between the output groups using
SELECT and select one of the two groups using SET. A double
tone sounds. Output group 1 has three different statuses, whilst
output group 2 only has two different statuses.
Flashing
status message: The IP alarm module responds when
triggered (on output group 1 only).
Lights up
wireless output: The IP alarm module sends a switch
command to the wireless socket when triggered.
Off
internal siren/info module: The IP alarm module sends the
activation/deactivation command when triggered.
You can switch the individual status using SELECT and confirm by
pressing SET. A double tone sounds.
Now activate training mode for the corresponding components
(see the instructions for these components for more details). The
corresponding input on the IP alarm module must then be triggered
through the recorder. This now sends the training signal, which is
acknowledged by the components.
Select ESC/DEL after assigning the relevant status and training for
both output groups. The main menu of the IP alarm module is
accessed again.
5.9

Restoring the factory defaults

Proceed as follows to delete all settings in the IP alarm module and
all detectors:
In the main programming menu, select item 8 (LED 8 lights up).
Note: LED7 is deactivated in main menu. After selecting LED6 the
indicator moves next to LED8 in programming menu.
Confirm by pressing SET. All LEDs flash.
Keep ESC/DEL pressed until the IP alarm module emits a double
tone as confirmation and LED 8 lights up. The programming and all
trained wireless detectors are now deleted.
Note: To exit menu item 8 without making a factory reset, only
press ESC/DEL briefly.
After restoring the factory default settings, exit the programming
mode by pressing ESC/DEL.
The power supply LED lights up and the fault LED lights up.
The accessory module beeps at short intervals.
Close both tamper contacts of the IP alarm module and wait until it
emits a double tone.