SMA SUNNY TRIPOWER 12000TL-US Instructions D'installation page 47

Masquer les pouces Voir aussi pour SUNNY TRIPOWER 12000TL-US:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SMA Solar Technology America LLC
Event number
Message, cause and corrective measures
7101
SD card defective
The SD memory card is not formatted.
Corrective measures:
7105
Param. setting failed
Parameters could not be set using the memory card. The inverter continues
feeding power into the grid.
Corrective measures:
7106
Update file defect.
Update file on the memory card is defective.
Corrective measures:
7102
Parameter file not found or defective
The parameter file was not found or is defective. The update failed. The in-
verter continues feeding power into the grid.
Corrective measures:
7110
No update file found
No update file has been found.
Corrective measures:
7201 to 7202
Data stor. not poss.
Internal error. The inverter continues to feed into the utility grid.
Corrective measures:
7303
Update main CPU failed
The cause must be determined by the Service.
Corrective measures:
Installation Manual
• Re-format the SD memory card.
• Re-save the files to the SD memory card.
• Ensure that the parameters are set correctly.
• Ensure that the SMA Grid Guard code is available.
• Reformat the memory card.
• Re-save the files to the memory card.
• Copy the parameter file to the correct folder again.
• Copy the update file to the memory card folder. Select the folder
\UPDATE.
• Contact the Service.
• Contact the Service.
10 Troubleshooting
STPTL-US-10-IA-xx-17
47

Publicité

Table des Matières
loading