RMDT10
8.1
Fault messages and signal tones
All faults are indicated with a warning symbol, a fault ID and a beep. The beeping
lasts for 2 minutes and is repeated every 30 minutes until the error has been rectified.
If multiple faults occur, the display shows the last fault. The underlying faults are dis-
played after the last fault has been confirmed.
Faults are indicated by a fault code with a warning symbol (
TFT display.
WARNING type fault messages
All faults of the WARNING type are reset automatically once the fault has been recti-
fied.
Code
Fault
W01
Defective temperature sensor in the
refrigerator compartment
W05
AC power not connected or
AC voltage < 190 V
W06
DC power not connected
W11
DC overvoltage (> 16 V).
Tank stop mode: Gas operation is
blocked for 15 minutes.
The door is opened for more than
2 minutes.
W10
+ beep
ERROR type fault messages
All faults of the ERROR type must be reset manually:
➤ Press the control knob for 2 seconds.
✓ A beep sounds.
✓ The error has been reset.
EN
) in the middle of the
Solution
Contact an authorized customer service.
Connect the refrigerator to AC or select a dif-
ferent energy type, e.g. gas or DC.
Connect the refrigerator to DC or select a dif-
ferent energy type, e.g. gas or AC.
Reduce the DC supply voltage.
Wait 15 minutes or switch to another
operating mode.
Close the door.
Troubleshooting
35