Operation

Connect the unit to a suitable power source, note
requirements on the ID plate. If an extension cord
is to be used, only waterproof cords are accepta-
ble.
With larger volumes of water, the evacuation pump
can be run continuously.
When used on smaller water volumes, the evacua-
tion pump is not run continuously. The container
is emptied when full by switching the evacuation
pump on. Care must be taken to turn off the pump
when the container is empty.
NOTE: The pump should not be allowed to run
without water fl ow.

Service

During cleaning and service of the unit, the unit
should be disconnected from the power supply.
The water pump is easily removed for cleaning.
Use only original fi lter bags.
The unit's vacuum motor is maintenance free.
Don't abuse the cord. Never pull the machine by
the cord.
If the suction is automatically shut off because the
container is full, the container must be emptied.
The evacuation pump will not generally empty
the container completely and care must be taken
to empty the container completely before trans-
porting
the unit. In order to empty the unit completely,
lift the motor top/cover off and lay the machine
down,see picture. Don't lay down the machine
without fi rst emptying the container completely.
The fi lter bag in the container should be changed
when it is 1/3 fi lled (max.). We recommend that
you always have the fi lter bag in the machine to
avoid unnecessary wear.
Use only original spare parts.
Filter Bag, standard
Examine the cord on a regular basis for damage.
The DC 50, 75 - W should be serviced and perfor-
mance tested at least once per year to maintain
proper operating condition. Worn parts must be
replaced. Do not take chances and compromise
safety by avoiding service.
DC 50,75-W, 10
Part No. 42174
Complete emptying of
container
Part No 94142-G

Publicité