Test load procedure for certification of 3.5 Series wood stove using ASTM E3053-17 according to EPA Alt-127 Low burn rate Stove lighting: 14.1 lbs Split the start-up fuel log into 8 pieces. Crisscross the 8 pieces on the brick, leaving some space between each wood pieces (3 in the bottom, 3 in the middle and 2 on the top).
Page 3
Loading: 34 lbs For the loading, put 2 logs at the back, 2 in the center and 2 in the front. The distance between the logs and the rear brick shall be approximately 1 inch. There should be one inch of air space between all the columns.
Page 4
LISTING REPORT FOR APPLICANT ISSUED: May 31 2019 2:49PM INSPECTION TESTS AND EVALUATION OF SBI Series 3.5(Solution 3.5, Escape 2100, HT-3000, Gateway 3500, Osburn 3500) Emissions and Efficiency - EPA (44826) RENDERED TO Stove Builder International Inc. 250, rue de Copenhague...
Page 5
6/26/2019 7:45:42 AM PRODUCT DESCRIPTION Product Covered: SBI Series 3.5(Solution 3.5, Escape 2100, HT-3000, Gateway 3500, Osburn 3500) Emissions and Efficiency - Product Description: Product covered Series 3.5 (Solution 3.5, Escape 2100, HT-3000, Gateway 3500, Osburn 3500)Wood Fuel Room Heaters Final emission results are as follows: Series 3.5...
Page 6
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM DRAWING INDEX Certificate of Conformity - SBI - Solution 3.5 Series Emissions and Efficiency - EPA Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 3 of 425...
Model Series 3.5 (Escape 2100, HT-3000, Solution 3.5, Osburn 3500, Product of samples of products taken Gateway 3500) from production (as applicable...
MANUFACTURING INFORMATION Product Covered The Solution Series 3.5 ( with models Solution 3.5, Escape 2100, HT-3000, Gateway 3500, Osburn 3500) is a Wood Fuel Room Heater. The models are constructed of sheet steel. The outer dimensions are 33 3/4-inches deep, 34 7/16-inches high, and 27 9/16-inches wide. The units have a door located on the front with a viewing glass.
Page 9
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM SIGNATURE PAGE Reported By: Reviewed By: Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 6 of 425...
Page 10
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM DRAWING INDEX 1 - Installation Manual Series 3.5 English 1 - Installation Manual Series 3.5 French 1 - Installation Manual Solution 3.5 English 1 - Installation Manual Solution 3.5 French 2 - Labels 3 - Drawings Solution 3.5 3 - Drawings Escape 2500...
Page 11
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH Installation and Operation Manual 3.5 SERIES ESCAPE 2100 GATEWAY 3500 HT-3000 OSBURN 3500 Wood stove certified US Environmental Protection Agency phase II 2020 cord wood <...
Page 12
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (2 OF 37) THANK YOU FOR CHOOSING THIS WOOD STOVE. As one of North America’s Contact local building or fire largest and most respected officials about restrictions wood stove and fireplace...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (3 OF 37) TABLE OF CONTENTS 1. Safety ............................5 2. General Information ........................ 6 2.1 Performances ......................... 6 2.2 Specifications ......................... 7 2.3 Materials .........................
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (4 OF 37) 8.3 Minimum Chimney Height ....................27 8.4 Chimney Location ......................27 8.5 Supply of Combustion Air ....................28 8.6 Installing the Chimney Connector ..................
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (5 OF 37) PART A - OPERATION AND MAINTENANCE 1. Safety • This stove has been tested for use with an open door in conjunction with a fire screen, sold separately.
Performances Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output. Models Escape 2100, Gateway 3500, HT-3000, Osburn 3500 Fuel Type Dry Cordwood Recommended heating area (sq. ft.)
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053 (2017). Materials The SBI team is committed to protecting the environment, so they do everything they can to use only materials in their products that will have no lasting negative impact on the environment.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (8 OF 37) The door and glass gaskets are fibreglass which is spun from melted sand. Black gaskets have been dipped into a solvent-free solution. Disposal at a landfill is recommended. The door glass is a 4 mm thick ceramic material that contains no toxic chemicals.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (9 OF 37) 3. Fuel Good firewood has been cut to the correct length for the stove, split to a range of sizes and stacked in the open until its moisture content is down to 15% to 20%.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (10 OF 37) Piece Size Firewood dries more quickly when it is split. Large unsplit rounds can take years to dry enough to burn.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (11 OF 37) Use these guidelines to find out if the firewood is dry enough to burn: − Cracks form at the ends of logs as they dry; −...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (12 OF 37) Wood Storage in the Pedestal This stove has been certified to store logs in the pedestal provided that the following requirements are met: •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (13 OF 37) Lighting Fires Each person heating with wood develops its own favorite way to light fires. Regardless of the method chosen, the goal should be to have a hot fire burning, quickly.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (14 OF 37) 5.2.2 Two Parallel Logs Method Two spit logs are placed in the firebox with a few sheets of twisted newspapers in between the logs.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (15 OF 37) Open the air control completely and close the door. Raking the coals is useful for two reasons. First, it brings them near where most of the combustion air enters the firebox.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (16 OF 37) As the air intake is reduced, the burn rate decreases. This has the effect of distributing the thermal energy of the fuel over a longer period of time.
Page 27
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (17 OF 37) 5.7.2 Long Lasting Fire For a fire that will last up to eight hours but will not produce intense heat, use soft wood and place the logs compactly in the firebox.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (18 OF 37) North-south loads allow more wood to be loaded at the same time. On the other hand, they break into smaller pieces faster.
Page 29
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (19 OF 37) When the insert runs at a low combustion rate, light brown stains may form, especially in the lower corners of the glass.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (20 OF 37) 6.2.3 Gasket The glass gasket is flat, adhesive-backed, woven fibreglass. The gasket must be centred on the edge of the glass.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (21 OF 37) 6.3.1 Adjustment In order for the insert to burn at its best efficiency, the door must provide a perfect seal with the firebox.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (22 OF 37) 6.3.2 Gasket It is important to replace the gasket with another having the same diameter and density to maintain a good seal.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (23 OF 37) important, therefore, to check the build-up in the chimney monthly until the rate of creosote formation is determined. Even if creosote forms slowly in the system, the chimney should be cleaned and inspected at least once each year.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (24 OF 37) PART B - INSTALLATION 7. Safety Information and Standards • The information given on the certification label affixed to the appliance always overrides the information published, in any other media (owner’s manual, catalogues, flyers, magazines and web sites).
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (25 OF 37) In addition, important information about the stove can be found (model, serial number, etc.). The certification label is located on the back of the stove. It is recommended to note the stove serial number on page 4 of this manual since it will be needed to precisely identify the version of the appliance in the event replacement parts or technical assistance is required.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (26 OF 37) 8.2.2 Factory-Built Metal Chimneys in Mobile Homes For use in a mobile home, this stove is to be connected to a 6"...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (27 OF 37) Minimum Chimney Height The top of the chimney should be tall enough to be above the air turbulence caused when wind blows against the house and its roof.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (28 OF 37) When it is cold outside, the warm air in the house is buoyant so it tends to rise. This creates a slight pressure difference in the house.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (29 OF 37) 8.5.2 Conventional House The safest and most reliable supply of combustion air for a wood stove is from the room in which it is installed.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (30 OF 37) Double wall chimney connectors are tested and certified. The rules for double wall pipe are found in the manufacturer’s installation instructions. These rules will be very different than those for single wall.
Page 41
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (31 OF 37) • Flue pipes must be at least 24 gauge in thickness. • Flue pipe joints should overlap 30 mm (1 1/4 in.) •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (32 OF 37) APPENDIx 1: OPTIONAL FRESH AIR INTAKE KIT INSTALLATION This mobile home approved stove requires installation of a fresh air intake kit (A) and an insulated fresh air intake pipe (HVAC type, must meet ULC S110 or UL 181 class 0 or class 1) (B), sold separately.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (33 OF 37) APPENDIx 2: OPTIONAL FIRE SCREEN INSTALLATION Open the door. Hold the fire screen by the two handles and bring it close to the door opening.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (34 OF 37) APPENDIx 3: AIR TUBES AND BAFFLE INSTALLATION Starting with the rear tube, lean and stove the right end of the secondary air tube into the rear right channel hole.
Page 45
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (35 OF 37) Note that secondary air tubes (B) can be replaced without removing the baffle board (A) and that all tubes are identical.
Page 46
6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (36 OF 37) SBI LIMITED LIFETIME WARRANTY SBI LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory.
Page 47
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH (37 OF 37) This document is available for free download on the manufacturer’s website. It is a copyrighted document. Stove Builder International inc. Resale is strictly prohibited.
6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH Manuel d’installation et d’opération SÉRIE 3.5 ESCAPE 2100 GATEWAY 3500 HT-3000 OSBURN 3500 Poêle à bois approuvé selon les exigences de la phase II 2020 bois de corde de l’agence de protection de l’environnement...
Page 49
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (2 OF 38) MERCI D’AVOIR CHOISI CE POÊLE À BOIS. Fabricant de poêles Consulter le code du international est l’un des plus bâtiment local ou contacter importants et des plus réputés le service des incendies pour...
Page 50
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (3 OF 38) TABLE DES MATIÈRES 1. Sécurité ........................... 5 2. Informations générales ......................6 2.1 Performances ........................6 2.2 Specifications ........................7 2.3 Matériaux ........................
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (4 OF 38) 8.4 Emplacement de la cheminée ..................28 8.5 Apport d’air de combustion .....................29 8.6 Installation du raccord de cheminée .................31 Annexe 1: Installation d’un ensemble d’entrée d’air frais optionnel ........
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (5 OF 38) PARTIE A – UTILISATION ET ENTRETIEN 1. Sécurité • Ce poêle a été mis à l’essai pour être utilisé la porte ouverte avec un pare-étincelles, vendu séparément.
Valeurs telles qu’obtenues en test, à l’exception de la superficie de chauffage recommandée, le volume de la chambre à combustion, le temps de combustion maximal et la puissance thermique maximale. Escape 2100, Gateway 3500, HT-3000, Osburn Modèles 3500 Type de combustible Bûches de bois sec...
Testé et certifié selon CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) et Draft ASTM E3053 (2017). Matériaux L’équipe de SBI s’est engagée à protéger l’environnement, de sorte qu’elle fait tout en son pouvoir pour n’utiliser dans ses produits que des matériaux qui n’auront aucun impact négatif durable sur l’environnement.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (8 OF 38) Les joints d’étanchéité de la porte et de la vitre sont faits de fibre de verre qui est tissée à partir de sable fondu.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (9 OF 38) En brûlant le bois complètement, le poêle libère toute l’énergie calorifique du bois, plutôt que de la gaspiller en fumée qui s’échappe par la cheminée. De plus, les caractéristiques de la chambre à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (10 OF 38) Le bois franc est meilleur pour les temps froids d’hiver lorsqu’il faut plus de chaleur et un cycle de combustion plus long.
Page 58
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (11 OF 38) Du bois de chauffage avec une teneur en humidité de 15% à 20% permettra au poêle d’atteindre son rendement le plus élevé.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (12 OF 38) 4. Utilisation du poêle Le taux de combustion minimum de cet appareil à bois a été défini par le fabricant et ne doit pas être modifié.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (13 OF 38) Entreposage du bois dans le piedestal Cet appareil a été certifié pour entreposer des bûches dans le piédestal, pourvu que les spécifications suivantes soient respectées: •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (14 OF 38) Allumer un feu Chaque personne qui chauffe au bois développe sa façon préférée de faire du feu. Peu importe la méthode choisie, le but devrait être d’avoir un feu chaud, rapidement.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (15 OF 38) 5.2.3 Deux bûches parallèles Placer deux bûches fendues dans la chambre à combustion, avec quelques feuilles de papier journal tordu entre les bûches.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (16 OF 38) La plupart des braises restantes seront situées au fond de la chambre à combustion, à l’opposé de la porte. Il faut donc déplacer ces braises vers la porte à l’aide d’une pelle, avant de remettre du bois.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (17 OF 38) Contrôle de l’admission d’air Lorsque le bois de chauffage, la chambre à combustion et la cheminée sont chauds, l’admission d’air peut être réduite pour obtenir une combustion stable.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (18 OF 38) Ce type de feu est bon pour les températures modérées et devrait fournir suffisamment de chaleur pendant environ quatre heures. C’est le bon moment pour utiliser du bois mou et éviter de surchauffer la maison.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (19 OF 38) Un temps de combustion plus long n’indique pas nécessairement que le rendement de l’appareil est bon. Il est préférable de faire de petits feux qui fourniront de trois à quatre heures de chaleur, plutôt que de remplir la chambre à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (20 OF 38) Matériaux réfractaires et coupe-feu Inspecter les briques ou les pierres réfractaires et le coupe-feu périodiquement. Remplacer ce qui est cassé...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (21 OF 38) 6.3.2 Remplacement La vitre utilisée est un verre céramique 4 mm d’épaisseur testée pour des températures pouvant atteindre 1400 °F.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (22 OF 38) Porte Afin d’obtenir un rendement optimal, la porte doit être parfaitement étanche avec la chambre à combustion. L’étanchéité de la porte peut être vérifiée en fermant et en verrouillant la porte sur un bout de papier.
Page 70
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (23 OF 38) Dévisser l’écrou (A). Retirer le loquet de porte (B) et la clavette (C). Retirer ou ajouter une rondelle (D) selon le besoin.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (24 OF 38) Système d’évacuation La fumée de bois se condense à l’intérieur de la cheminée, formant un dépôt inflammable appelé créosote.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (25 OF 38) 6.5.3 Feu de cheminée L’entretien et l’inspection régulière du système de cheminée peuvent éviter les feux de cheminée. Si un feu de cheminée se déclare, procéder comme suit : Fermer la porte et le contrôle d’admission d’air du poêle;...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (26 OF 38) Règlements régissant l’installation d’un poêle Lorsqu’il est installé et utilisé tel que décrit dans les présentes instructions, ce poêle à bois convient comme appareil de chauffage autonome pour installation résidentielle.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (27 OF 38) 8.2.1 Cheminées de métal préfabriquées Ces cheminées sont souvent appelées cheminées «à haute température», parce qu’elles possèdent caractéristiques spéciales pour...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (28 OF 38) 8.2.3 Cheminées de maçonnerie Le poêle peut aussi être raccordé à une cheminée de maçonnerie, pourvu que la cheminée soit conforme aux règles de construction du code du bâtiment local.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (29 OF 38) Figure 12: Bonne conception du système Figure 13: Conception de système acceptable Lorsqu’il fait froid dehors, l’air chaud de la maison, qui est plus léger, tend à s’élever. Ceci crée une légère différence de pression dans la maison.
Page 77
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (30 OF 38) 8.5.1 Maisons mobile Ce poêle est homologué et «approuvé pour maison mobile». Il doit donc avoir un conduit d’apport d’air de combustion de l’extérieur.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (31 OF 38) Dans certaines conditions venteuses, de la pression négative près du capuchon contre les intempéries à l’extérieur de la maison peut aspirer la fumée chaude du poêle dans le conduit, vers l’extérieur.
Page 79
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (32 OF 38) • Longueur maximum de tuyau horizontal : 3 m (10 pi.) incluant les coudes. • Dégagement minimum par rapport aux matériaux inflammable : 450 mm (18 po.) Le dégagement minimum peut être réduit de 50 pour cent à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (33 OF 38) ANNExE 1: INSTALLATION D’UN ENSEMBLE D’ENTRÉE D’AIR FRAIS OPTIONNEL Ce poêle, approuvé maison mobile, requiert l’installation d’un ensemble d’entrée d’air frais (A) et d’un tuyau isolé...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (34 OF 38) ANNExE 2: INSTALLATION DU PARE-ÉTINCELLES OPTIONNEL Ouvrir la porte. Tenir le pare-étincelles à l’aide des deux poignées et approchez-le de l’ouverture de porte.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (35 OF 38) ANNExE 3: INSTALLATION DES TUBES D’AIR ET DU COUPE-FEU En commençant vers l’arrière, Inclinez et insérez le tube d’air secondaire arrière dans le trou du fond de la canalisation droite.
Page 83
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (36 OF 38) Prenez note que n’importe quel tube (B) peut être remplacé sans retirer le coupe-feu (A) et que les tubes sont tous identiques.
1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (37 OF 38) GARANTIE À VIE LIMITÉE SBI GARANTIE À VIE LIMITÉE SBI La garantie du fabricant ne s’applique qu'à l’acheteur au détail original et n’est pas transférable. La présente garantie ne couvre que les produits neufs qui n’ont pas été...
Page 85
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SERIES 3.5 FRENCH (38 OF 38) Ce manuel peut être téléchargé gratuitement à partir du site web du manufacturier. Il s’agit d’un document dont les Fabricant de poêles International inc.
Page 86
St-Augustin-de-Desmaures (Quebec) Canada G3A 2H3 After-sale service: 418-908-8002 E-mail: tech@sbi-international.com READ AND KEEP THIS MANUAL FOR REFERENCE This manual is available for free download on the manufacturer’s web site. It is a copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this...
Page 87
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (2 OF 57) THANK YOU FOR CHOOSING THIS ENERZONE WOOD STOVE As one of North America’s largest and most respected wood stove and fireplace manufacturers, Stove Builder International takes pride in the quality and performance of all its products.
Page 88
Zone Heating and How to Make it Work for You ..............9 The Benefits of Low Emissions and High Efficiency ............9 The SBI Commitment to You and the Environment ............9 2.5.1 What is Your New Stove Made Of? ................9 3 Fuel ....................
Page 89
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (4 OF 57) Stove Maintenance ......................20 5.1.1 Cleaning Door Glass ....................20 5.1.2 Door adjustment ......................21 5.1.3 Replacing the Door Gasket ..................22 5.1.4 Replacing the Glass Gasket and/or the Glass ..............
Page 90
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (5 OF 57) Appendix 2: Installing the Optional Door Overlay ..... 45 Appendix 3: Installing Trims ............46 Appendix 4: Installing the Optional Air Mate (AC01230) ... 47 Appendix 5: Installing the Optional Fresh Air Intake Kit (AC01316 / AC01336) ..............
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (6 OF 57) PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 Safety Information 1.1 Summary of Operation and Maintenance Cautions and Warnings •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (7 OF 57) General Information on Solution 3.5 (EB00053) 2.1 Appliance performance Fuel type Dry cordwood Recommended heating area 1,000 to 2,700 ft (93 to 223 m Firebox volume 3.7 ft...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (8 OF 57) 2.2 General Features Maximum log length 22 in (559 mm) east-west* Flue outlet diameter 6 in (152 mm) Recommended connector pipe diameter 6 in (152 mm) Baffle material...
2.5 The SBI Commitment to You and the Environment The SBI team are committed to protecting the environment, so we do everything we can to use only materials in our products that will have no lasting negative impact on the environment.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (10 OF 57) 3 Fuel 3.1 Materials That Should Not be Burned • GARBAGE OF ANY KIND, • COAL OR CHARCOAL, •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (11 OF 57) 3.2.3 Log Length Logs should be cut about 1” (25 mm) shorter than the firebox so they fit in easily. Pieces that are even slightly too long make loading the stove very difficult.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (12 OF 57) 3.2.5 How to Dry Firewood Firewood that is not dry enough to burn is the cause of most complaints about wood stoves. The complaints usually involve a lack of heat and dirty door glass.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (13 OF 57) 3.2.6 Judging Firewood Moisture Content You can find out if some firewood is dry enough to burn by using these guidelines: •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (14 OF 57) 4 Operating Your Stove 4.1 Your First Fires Two things will happen as you burn your first few fires; the paint cures and the internal components of the stove are conditioned.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (15 OF 57) 4.2.2 The Top Down Fire The top down fire starting method solves two problems with the conventional method: first, it does not collapse and smother itself as it burns;...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (16 OF 57) when the wood was loaded. Do not attempt to produce a steady heat output by placing a single log on the fire at regular intervals.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (17 OF 57) Remove ash first, and then rake charcoal towards the front of the firebox before loading so that it will ignite the new load.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (18 OF 57) 4.3.6 Building Different Fires for Different Needs Using the air control is not the only way to match the stove’s heat output to the heat demand. Your house will need far less heat in October than in January to be kept at a comfortable temperature.
Page 104
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (19 OF 57) 4.3.6.4 Maximum Burn Cycle Times The burn cycle time is the period between loading wood on a coal bed and the consumption of that wood back to a coal bed of the same size.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (20 OF 57) 5 Maintaining Your Wood Heating System 5.1 Stove Maintenance Your new stove will give many years of reliable service if you use and maintain it correctly. Some of the internal components of the firebox, such as firebricks, baffles and air tubes, will wear over time under intense heat.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (21 OF 57) 5.1.2 Door adjustment In order for your stove to burn at its best efficiency, the door must provide a perfect seal with the firebox.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (22 OF 57) 5.1.3 Replacing the Door Gasket It is important to maintain the gasket in good condition. After a year or more of use, the door gasket will compress and become hard, which may allow air to leak past it.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (23 OF 57) Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (24 OF 57) 5.2.3 Cleaning the Chimney Chimney cleaning can be a difficult and dangerous job. don’t have experience cleaning chimneys, you might want to hire a professional chimney sweep to clean and inspect the system for the first time.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (25 OF 57) PART B - INSTALLATION 6 Safety Information 6.1 Summary of Installation Cautions and Warnings • THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES).
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (26 OF 57) 6.2 Regulations Covering Stove Installation When installed and operated as described in these instructions, the Solution 3.5 wood stove is suitable for use as a freestanding heater in residential installations.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (27 OF 57) 7.2 Clearances to Walls and Ceiling The clearances to combustible walls may be slightly different in Canada and the U.S.A. and may also differ depending on whether you use single or double wall flue pipe.
Page 113
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (28 OF 57) Clearances with ceiling (L) lowered to 76" (193 cm) APPLIANCE CLEARANCES APPLIANCE CLEARANCES (INSTALLATION WITH SINGLE WALL (INSTALLATION WITH DOUBLE PIPE CONNECTOR) WALL PIPE CONNECTOR)
Page 114
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (29 OF 57) If the above clearances are met, then the distances measured from the flue outlet will be: DISTANCES* FROM PIPE CONNECTOR TO THE COMBUSTIBLE MATERIALS CANADA 17¾"...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (30 OF 57) Clearances to combustible materials and floor protection 7.3 Floor protector If the stove is to be installed on top of a combustible floor, it must be guarded by a non combustible material as shown on figure 1.3 (see the dotted line area).
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (31 OF 57) Important Note: Addition required to the floor protection when the stove is installed in a mobile home and assembled on legs version only: In addition to meeting the minimum size of the floor protection, the stove must be...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (32 OF 57) 7.4.1 Shield Construction Rules See figure Clearances for shield construction to match each letter to a clearance. - Adhesives used in shield construction must not ignite or lose adhesive qualities at temperatures likely to be encountered.
Page 118
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (33 OF 57) Clearances for shield construction Solution 3.5 Installation and Operation Manual Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 115 of 425...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (34 OF 57) 7.4.2 Table of Clearance Reduction Percentages Clearances may be reduced by these percentages Sides Top % Type of shield and rear % (ceiling) Can/USA...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (35 OF 57) 8 The Venting System 8.1 General The venting system, made up of the chimney and the connecting pipe between the stove and the chimney, acts as the engine that drives your wood heating system.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (36 OF 57) 8.2.2 Factory-built Metal Chimneys in mobile homes For use in a mobile home, this stove is to be connected to a 6”...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (37 OF 57) 8.3 Minimum Chimney Height The top of the chimney should be tall enough above turbulence caused when wind blows against the house and its roof.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (38 OF 57) 8.4.2 Why the chimney should penetrate the highest heated space When it is cold outside, the warm air in the house is buoyant so it tends to rise. This tendency of warm air to rise creates a slight pressure difference in the house.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (39 OF 57) 8.5.1 Combustion Air Supply in Mobile Homes Only a wood stove certified and labelled as ‘mobile home approved’ may be installed in a mobile home.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (40 OF 57) 8.6.1 Installation of Single Wall Chimney Connector The chimney connector assembly has been called ‘the weak link’ in the safety of wood heating systems because failure to install the connector properly (which has been common in the past) can result in house fires.
Page 126
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (41 OF 57) The rules below are based on those found in the CSA B365 installation code. Please carefully follow these installation instruction rules, or those enforced where you live. •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (42 OF 57) Appendix 1: Installing the Optional Legs or Pedestal The leg or pedestal kit must be assembled to the firebox before positioning the stove. See installation instructions below: 1- Remove the firebricks, the ash dump plug and the loading door from the stove to...
Page 128
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (43 OF 57) Leg kit installation: 4- Secure each leg (A) on support (B) using (2) washers (C) and (2) nuts (D) supplied in the kit.
Page 129
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (44 OF 57) Pedestal kit installation: Follow step 1, 2 and 3 of the leg kit installation. 5- Secure pedestal base underside of the firebox using the bolts, washers and nuts removed in...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (45 OF 57) Appendix 2: Installing the Optional Door Overlay In order to complete the assembly of your Solution 3.5 wood stove, you need to install the door overlay.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (46 OF 57) Appendix 3: Installing Trims Your freestanding Enerzone wood stove is equipped with decorative u-shaped trims. See installation instructions below: 1- Remove the 7 screws that secure the side panels and the rear top air deflector.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (47 OF 57) Appendix 4: Installing the Optional Air Mate (AC01230) Most freestanding Enerzone wood stoves can be equipped with an optional air mate. This device accumulates heat and increases the air flow.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (48 OF 57) Appendix 5: Installing the Optional Fresh Air Intake Kit (AC01316 / AC01336) This mobile home approved stove requires installation of a fresh air intake kit (A) and an insulated fresh air intake pipe (B), sold separately.
Page 134
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (49 OF 57) Fresh air intake kit (AC01316) for installation on the Fresh air intake kit (AC01336) bottom of wood stove on legs for installation on the bottom of pedestal wood stove model Solution 3.5 Installation and Operation Manual...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (50 OF 57) Appendix 6: Installing the Optional Fire Screen (AC01315) Open the door. Hold the fire screen by the two handles and bring it close to the door opening.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (51 OF 57) Appendix 7: Installation and Use of the Optional Blower and Thermodisc An optional blower can be installed on the back of the stove to increase the flow of air past heat exchange surfaces and to help circulate warm air in the room.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (52 OF 57) Appendix 8: Installation of Secondary Air Tubes and Baffle 1- Starting with the rear tube, lean and insert the right end of the secondary air tube into the rear right channel hole.
Page 138
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (53 OF 57) Note that secondary air tubes (B) can be replaced without removing the baffle board (A). Solution 3.5 Installation and Operation Manual Stove Builder International Inc.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (54 OF 57) Appendix 9: Exploded Diagram and Parts List Solution 3.5 Installation and Operation Manual Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 136 of 425...
Page 140
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (55 OF 57) IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your stove, please provide the model number and the serial number. We reserve the right to change parts due to technology upgrade or availability.
Page 141
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (56 OF 57) Item Description 32 PL24012PN ENERZONE NICKEL PLATED CAST IRON LEG WITH LEVELING BOLT 32 24012 BLACK CAST IRON LEG WITH LEVELING BOLT 33 30050 LEVELING BOLT 3/8-16 X 1 1/2"...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH (57 OF 57) ENERZONE LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory.
Page 143
St-Augustin-de-Desmaures (Québec) Canada G3A 2H3 Service après-vente : 418-908-8002 Courriel : tech@sbi-international.com LIRE LE PRÉSENT MANUEL ET LE CONSERVER POUR CONSULTATION Ce manuel peut être téléchargé gratuitement à partir du site web du manufacturier. Il s’agit d’un document dont les droits d’auteurs sont protégés. La revente de ce manuel est formellement interdite.
Page 144
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (2 OF 58) MERCI D’AVOIR CHOISI CE POÊLE À BOIS ENERZONE Fabricant de poêles international est l’un des plus importants et des plus réputés fabricants de poêles à...
Page 145
Chauffage par zone- De quelle façon vous pouvez en profiter .......... 9 Les avantages des faibles émissions et du haut rendement ..........9 L’engagement de SBI envers vous et l’environnement ............ 10 2.5.1 De quoi est fait votre nouveau poêle? ..............10 Combustible ................
Page 146
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (4 OF 58) Entretien de votre système de chauffage au bois ....21 Entretien du poêle ......................21 5.1.1 Nettoyage de la vitre ....................21 5.1.2 Ajustement de la porte .....................
Page 147
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (5 OF 58) Annexe 1 : Installation des pattes ou du piédestal (option) ..43 Annexe 2 : Installation du revêtement de porte (option) ..46 Annexe 3 : Installation des panneaux décoratifs ......
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (6 OF 58) PARTIE A – UTILISATION ET ENTRETIEN S.V.P., référez-vous à la Partie B pour les directives d’installation. 1 Sécurité 1.1 Résumé...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (7 OF 58) 2 Renseignements généraux du Solution 3.5 (EB00053) 2.1 Performance de l’appareil Type de combustible Bûches de bois sec Superficie de chauffage recommandée 1,000 à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (8 OF 58) 2.2 Caractéristiques générales Longueur maximale des bûches 22 po (559 mm) orientation est-ouest* Diamètre de la buse de raccordement 6 po (152 mm) Diamètre du tuyau de raccordement recommandé...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (9 OF 58) 2.3 Chauffage par zone- De quelle façon vous pouvez en profiter Votre nouveau poêle à bois Solution 3.5 sert au chauffage des locaux, ce qui signifie qu’il est prévu pour chauffer le secteur où...
(10 OF 58) 2.5 L’engagement de SBI envers vous et l’environnement L’équipe de SBI s’est engagée à protéger l’environnement, de sorte que nous faisons tout en notre pouvoir pour n’utiliser dans nos produits que des matériaux qui n’auront aucun impact négatif durable sur l’environnement.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (11 OF 58) 3 Combustible 3.1 Les matériaux qu'il ne faut pas brûler LES DÉCHETS QUELS QU’ILS SOIENT; • DU CHARBON OU DU CHARBON DE BOIS; •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (12 OF 58) 3.2.3 Longueur des bûches Les bûches devraient être coupées pour avoir environ 1 po. de moins que la chambre à combustion, de façon à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (13 OF 58) 3.2.5 Comment faire sécher le bois de chauffage Le bois de chauffage qui n’est pas suffisamment sec est la cause de la plupart des plaintes concernant les poêles à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (14 OF 58) 3.2.6 Comment évaluer la teneur en humidité du bois de chauffage Vous pouvez savoir si du bois de chauffage est suffisamment sec pour brûler à l'aide des indications suivantes : •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (15 OF 58) 4 Utilisation du poêle 4.1 Les premières attisées Deux choses vont se produire lorsque vous ferez les premières attisées, la peinture durcira et les composantes intérieures se conditionneront.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (16 OF 58) NE PAS LAISSER LE POÊLE SANS SURVEILLANCE LORSQUE LA PORTE EST LÉGÈREMENT OUVERTE LORS DE L'ALLUMAGE. TOUJOURS FERMER LA PORTE APRÈS L’ALLUMAGE.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (17 OF 58) température diminue graduellement avec la progression du feu. L’augmentation et la diminution de la température peuvent être synchronisées avec vos routines domestiques. Par exemple, la température de la zone peut être plus fraîche lorsque vous êtes actif, lorsque vous faites du ménage ou de la cuisson et elle peut être plus chaude lorsque vous êtes inactif, quand vous lisez ou regardez la télévision.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (18 OF 58) nouvelle charge rapidement et deuxièmement, les braises ne seront pas étouffées par la nouvelle charge de bois. Si vous étalez simplement les braises, la nouvelle charge brûlera en amortissant longtemps avant de s’enflammer.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (19 OF 58) Au fur et à mesure que vous réduisez l'admission d'air de combustion, deux choses importantes se produisent. Tout d’abord, le taux de combustion diminue, ce qui répartit l’énergie thermique du combustible sur une plus grande période de temps.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (20 OF 58) 4.3.6.3 Des feux qui donnent beaucoup de chaleur pour le temps froid Lorsque les besoins de chauffage sont élevés par temps froid, il vous faudra un feu stable et vif. C’est le temps de brûler vos plus grosses bûches de bois franc si vous en avez.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (21 OF 58) 4.3.6.5 Des feux dont le bois est placé droit (orientation nord-sud) par rapport à des feux dont le bois est placé sur le travers (orientation est-ouest) Dans les chambres à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (22 OF 58) dans votre façon de faire ou votre combustible. Des taches sur la vitre indiquent une combustion incomplète du bois, ce qui signifie aussi plus de rejets de fumée et une formation plus rapide de créosote dans la cheminée.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (23 OF 58) 5.1.3 Remplacement du joint d’étanchéité de la porte Après un an ou plus d’usage, le joint d'étanchéité de la porte se comprimera et deviendra dur, ce qui peut permettre à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (24 OF 58) Ne maltraitez pas la porte en frappant dessus ou en la claquant. Ne pas se servir de l’unité si la vitre est manquante, craquée ou brisée.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (25 OF 58) 5.2.3 Ramonage de la cheminée Le ramonage de la cheminée peut être difficile et dangereux. Si vous n’avez pas d’expérience dans ramonage...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (26 OF 58) PARTIE B - INSTALLATION 6 Sécurité 6.1 Résumé des mises en garde et avertissements concernant l’installation LES INFORMATIONS INSCRITES SUR LA PLAQUE D’HOMOLOGATION DE L’APPAREIL •...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (27 OF 58) 6.2 Règlements régissant l’installation d’un poêle Lorsqu’il est installé et utilisé tel que décrit dans les présentes instructions, le poêle à bois Solution 3.5 convient comme appareil de chauffage autonome pour installation résidentielle.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (28 OF 58) 7.2 Dégagements de l'appareil aux matériaux combustibles Les dégagements par rapport aux murs inflammables peuvent être légèrement différents entre le Canada et les É.-U.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (29 OF 58) Dégagements lorsque le plafond (L) est abaissé à 76" (193 cm) DÉGAGEMENTS DE L’APPAREIL DÉGAGEMENTS DE L’APPAREIL (INSTALLATION AVEC TUYAU (INSTALLATION AVEC TUYAU PAROI SIMPLE)
Page 172
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (30 OF 58) Si les dégagements ci-dessus sont rencontrés, alors les distances mesurées à partir de la buse seront : DISTANCES* DE LA BUSE AVEC TUYAU À...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (31 OF 58) Dégagements aux matériaux combustibles et protection du plancher 7.3 Protection du plancher Votre poêle est conçu pour empêcher le plancher de surchauffer. Il faut toutefois le placer sur une surface ininflammable pour protéger le plancher des tisons chauds qui pourraient tomber du poêle lors du chargement et de l’entretien.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (32 OF 58) Note importante : Addition requise à la protection de plancher lorsque le poêle installé maison mobile assemblée version pattes seulement : En plus de respecter la dimension minimale...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (33 OF 58) 7.4.1 Règles de construction de l’écran Consultez la figure Dégagements pour construction de l’écran afin d’associer chaque lettre au dégagement correspondant.
Page 176
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (34 OF 58) Dégagements pour construction de l’écran Manuel d’installation et d’utilisation du Solution 3.5 Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 173 of 425...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (35 OF 58) 7.4.2 Tableau des pourcentages de réduction de dégagement Voici les pourcentages de réduction des dégagements permis Côtés Dessus Type d’écran et arrière...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (36 OF 58) 8 Le système d’évacuation 8.1 Conseils généraux Le système d’évacuation, composé de la cheminée et du tuyau qui raccorde le poêle à la cheminée, agit comme le moteur qui entraîne votre système de chauffage au bois.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (37 OF 58) 8.2.2 Cheminées de métal préfabriquées pour les maisons mobiles Pour une utilisation dans une maison mobile, ce poêle doit être raccordé à un tuyau préfabriqué...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (38 OF 58) 8.3 Hauteur minimum de la cheminée L'extrémité de la cheminée doit être suffisamment haute pour dépasser la turbulence d’air causée par le vent contre la maison et le toit.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (39 OF 58) 8.4.2 Pourquoi est-ce que la cheminée devrait traverser la partie chaude la plus élevée Lorsqu’il fait froid dehors, l’air chaud de la maison qui est plus léger tend à s’élever. Cette tendance qu’a l’air chaud à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (40 OF 58) 8.5.1 Apport d’air de combustion dans les maisons mobiles Seul un poêle homologué et portant l’étiquette «approuvé pour maison mobile» peut être installé...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (41 OF 58) 8.6.1 Installation d’un raccord de cheminée à paroi simple L’ensemble du raccord de cheminée a été appelé «le maillon faible» dans la sécurité des systèmes de chauffage au bois, parce que si le raccord est mal installé...
Page 184
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (42 OF 58) Les règles ci-dessous sont basées sur celles que l’on retrouve dans le code d’installation ACNOR B365. Prière de suivre soigneusement ces instructions d’installation ou celles qui sont en vigueur chez vous.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (43 OF 58) Annexe 1 : Installation des pattes ou du piédestal (option) Avant de localiser le poêle à bois, il est suggéré d’assembler les pattes ou le piédestal. Voir ci- dessous pour les instructions d’installation : 1- Retirez les briques, le bouchon à...
Page 186
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (44 OF 58) Assemblage des pattes : 4- Installez chaque patte (A) sur le support (B) à l’aide de 2 rondelles (C) et 2 écrous (D) fournis avec le kit.
Page 187
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (45 OF 58) Assemblage du piédestal : Suivez les étapes 1, 2 et 3 de l’assemblage de pattes. 5- Installez la base du piédestal en dessous de l’appareil à...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (46 OF 58) Annexe 2 : Installation du revêtement de porte (option) Afin de compléter l’assemblage de votre poêle à bois autoportant Solution 3.5, vous aurez besoin d’installer le revêtement de porte.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (47 OF 58) Annexe 3 : Installation des panneaux décoratifs Votre poêle à bois autoportant Enerzone est doté de panneaux décoratifs. Voir ci-dessous comment les installer : 1- Dévissez les 7 vis qui retiennent les panneaux de côté...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (48 OF 58) Annexe 4 : Installation de l’échangeur de chaleur supérieur (option AC01230) La plupart des poêles à bois autoportants Enerzone peuvent être munis d’un échangeur de chaleur supérieur.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (49 OF 58) Annexe 5 : Installation d’un ensemble d’entrée d’air frais 5" (option AC01316 / AC01336) Ce poêle approuvé maison mobile requiert l’installation d’un ensemble d’entrée d’air frais 5’’ (A) et d’un tuyau isolé...
Page 192
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (50 OF 58) Installation de l’ensemble d’entrée d’air frais (AC01316) Installation de l’ensemble d’entrée en dessous pour modèle sur pattes: d’air frais (AC01336) en dessous pour modèle sur piédestal: Manuel d’installation et d’utilisation du Solution 3.5...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (51 OF 58) Annexe 6 : Installation du pare-étincelles (option AC01315) Ouvrez la porte. Tenez le pare-étincelles à l’aide des deux poignées approchez-le...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (52 OF 58) Annexe 7 : Installation et utilisation du ventilateur (option AC01000) et du thermodisque (option AC02055) Un ventilateur optionnel peut être installé derrière le poêle pour accroître la circulation d’air dans l’échangeur de chaleur et améliorer la circulation d’air chaud dans la pièce.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (53 OF 58) Annexe 8 : Installation des tubes d’air secondaires et du coupe-feu 1- En commençant vers l’arrière, Inclinez et insérez le tube d’air secondaire arrière dans le trou du fond de la canalisation droite.
Page 196
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (54 OF 58) Prenez note que n’importe quel tube (B) peut être remplacé sans retirer le coupe-feu (A). Manuel d’installation et d’utilisation du Solution 3.5 Stove Builder International Inc.
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (55 OF 58) Annexe 9 : Vue éclatée et liste de pièces Manuel d’installation et d’utilisation du Solution 3.5 Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 194 of 425...
Page 198
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (56 OF 58) IMPORTANT: IL S'AGIT D’INFORMATIONS ACTUALISÉES. Lors de la demande de service ou de pièces de remplacement pour votre poêle, s'il vous plaît fournir le numéro de modèle et le numéro de série.
Page 199
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (57 OF 58) Item Description Qté 32 PL24012PG PATTE EN FONTE ENERZONE PLAQUÉE OR AVEC BOULON DE NIVELAGE 32 PL24012PN PATTE EN FONTE ENERZONE PLAQUÉE ARGENT AVEC BOULON DE NIVELAGE 32 24012 PATTES NOIRE EN FONTE AVEC BOULON DE NIVELAGE 33 30050...
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 1 - INSTALLATION MANUAL SOLUTION 3.5 FRENCH (58 OF 58) GARANTIE À VIE LIMITÉE ENERZONE La garantie du fabricant ne s’applique qu'à l’acheteur au détail original et n’est pas transférable. La présente garantie ne couvre que les produits neufs qui n’ont pas été...
Page 201
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 2 - LABELS Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 198 of 425...
Page 202
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 2 - LABELS (2 OF 5) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 199 of 425...
Page 203
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 2 - LABELS (3 OF 5) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 200 of 425...
Page 204
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 2 - LABELS (4 OF 5) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 201 of 425...
Page 205
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 2 - LABELS (5 OF 5) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 202 of 425...
Page 206
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 258 of 425...
Page 207
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (2 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 259 of 425...
Page 208
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (3 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 260 of 425...
Page 209
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (4 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 261 of 425...
Page 210
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (5 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 262 of 425...
Page 211
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (6 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 263 of 425...
Page 212
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (7 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 264 of 425...
Page 213
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (8 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 265 of 425...
Page 214
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (9 OF 19) Guillaume Thibodeau-Fortin Guillaume Thibodeau-Fortin Envoyé: 3 mai 2018 12:20 À: 'Sanchez, Rafael' 'Claude Pelland Intertek' Objet: RE: 30-days notification - 3.4 series Hi Rafael, We had a safety issue with the stove earlier this week so we need to delay the certification planned on May 7 .
Page 215
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (10 OF 19) [Numéro de page] Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 267 of 425...
Page 216
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (11 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 268 of 425...
Page 217
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (12 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 269 of 425...
Page 218
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (13 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 270 of 425...
Page 219
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (14 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 271 of 425...
Page 220
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (15 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 272 of 425...
Page 221
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (16 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 273 of 425...
Page 222
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (17 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 274 of 425...
Page 223
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (18 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 275 of 425...
Page 224
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM APPENDIX I - EPA CORRESPONDANCE (19 OF 19) Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 276 of 425...
Page 225
6/26/2019 7:45:42 AM PRODUCT EVALUATION REPORT 103536746MTL-003 STOVE BUILDER INTERNATIONAL PRODUCT EVALUATION PRODUCT EVALUATED ESCAPE 2100, HT-3000, GATEWAY 3500, OSBURN 3500 EVALUATION PROPERTY U.S. ENVIRONMENTAL PROTECTION AGENCY 40 CFR PART 60 REPORT NUMBER 103536746-MTL003 ORIGINAL ISSUE DATE 02/11/19 LAST REVISED DATE...
Page 226
250 rue de Copenhague St-Augustin-de-Desmaures, QC G3A 2H3, Canada Contact Person: Guillaume Thibodeau-Fortin Tel: 1-418-878-3040 x5224 Email: gthibodeaufortin@sbi-international.com Table of Contents Introduction ..........................3 Product and Assembly Description ..................3 2.1. Product Description: ......................3 2.2. Product Traceability: ......................3 2.3.
Intertek Testing Services NA Ltd./Inc. (Intertek) is conducting a product evaluation for Stove Builder International, on Escape 2100, HT-3000, Gateway 3500, Osburn 3500, to evaluate if the differences with the previously certified Solution 3.5 will increase particulate matter emission rate limit. The evaluation is being conducted to determine if items listed in U.S.
Conclusion Intertek has conducted this product evaluation for Stove Builder International, on Escape 2100, HT-3000, Gateway 3500 and Osburn 3500, to evaluate if the differences with the previously certified Solution 3.5 are likely to increase particulate matter emission rate limit.
Page 229
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM PRODUCT EVALUATION REPORT 103536746MTL-003 (5 OF 50) 1829, 32nd AVenue Lachine, Quebec H8T 3J1 Telephone: (514)631-3100 Facsimile: (514)631-1133 www.intertek.com/building PRODUCT EVALUATION FOR STOVE BUILDER INTERNATIONAL Report No.: 103536746-MTL003 Date: 02/11/19 Based on the information contained and referenced herein, it is Intertek’s professional judgment based on sound engineering principles that the following is true:...
6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 STOVE BUILDER INTERNATIONAL INC. TEST REPORT SCOPE OF WORK EPA EMISSIONS TESTING/ 3.5 SERIES (SOLUTION 3.5, OSBURN 3500, GATEWAY 3500, ESCAPE 2100, HT-3000)/WOOD FUEL ROOM HEATERS. REPORT NUMBER 103536746MTL-002 TEST DATE(S) 05/22/18 - 05/25/18 ISSUE DATE...
Page 233
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (2 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 REPORT ISSUED TO STOVE BUILDER INTERNATIONAL, INC.
Page 234
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (3 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 SECTION 2 SUMMARY OF TEST RESULTS...
Page 235
On May 18th 2018, the unit was set-up for testing. SECTION 5 EQUIPMENT Equipment Calibration Due Number Handheld Thermocouple Thermometer SBI-004 April 19, 2019 ±0.5 Floor scale SBI-014 March 31, 2019 ± 0.022 kg DGM system 1 SBI-046 April 25, 2019 ±2% F.S.
Page 236
8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 Pressure transmitter SBI-294 June 16, 2018 ±9.5e-003 psi Vacuum transmitter SBI-301 June 16, 2018 ±6.5e-003 in.HG Vacuum transmitter SBI-302 June 16, 2018 ±6.5e-003 in.HG...
Page 237
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (6 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 AIR SUPPLY SYSTEM Combustion air enters at the bottom of the heater, which is directed to the firebox.
Page 238
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (7 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 FIGURE 1 –...
Page 239
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (8 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 Particulates were sampled in strict accordance with ASTM E2515-2011.
Page 240
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (9 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 TEST METHOD PROCEDURES LEAK CHECK PROCEDURES...
Page 241
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (10 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 SECTION 8 TEST CALCULATIONS...
Page 242
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (11 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 ...
Page 243
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (12 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 = Volume of gas sample as measured by dry gas meter, dcm (dcf).
Page 244
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (13 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 TOTAL PARTICULATE WEIGHT –...
Page 245
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (14 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 MU OF c = BG...
Page 246
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (15 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 = duct width, m The air flow velocity shall be calculated as follows:...
Page 247
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (16 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 = ∑(Δe ×...
Page 248
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (17 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 The air control was opened for 16.5 minutes or when 15% of the load weight has been consumed, and then set at the lowest burn rate.
Page 249
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (18 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 BURN VELOCITY...
Page 250
The emission rate of 1.37 g/hr meets the EPA requirements for the Step 2 limits. Solution 3.5 is a representative unit of the 3.5 series made of SOLUTION 3.5, OSBURN 3500, GATEWAY 3500, ESCAPE 2100, HT-3000. Version: 05/10/17 Page 19 of 21 GFT-OP-10c Stove Builder International Inc.
Page 251
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (20 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 SECTION 12 PHOTOGRAPHS...
Page 252
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM TEST REPORT 103536746MTL-002 (21 OF 21) 8431 Murphy Drive Middleton, WI 53562 Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC. Report No.: 103536746MTL-002 Date: 07/13/18 SECTION 13 REVISION LOG...
Page 253
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM COMPONENTS ETL Mark Minimum Labeling Requirements (new Intertek Mark) MINIMUM MARKING REQUIREMENTS FOR PRODUCTS BEARING THE ETL MARK The ETL Listing Certification Mark Label consists of the following four items: The ETL Certification Mark with “US”...
Page 254
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM In the case where a discrepancy exists between the product and the Listing Report, the Listing Report currently on the SpecDirect website will be considered correct, and therefore the Applicant has the responsibility for making the necessary corrections so that the product will meet the specifications stated herein.
Page 255
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM and certification and owns rights to Listing Reports. Authorization to Mark - The term Authorization to Mark (“ATM”) shall mean a written document from Intertek that authorizes the Manufacturer to apply an Intertek certification mark to a specific product.
Page 256
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM Certification Mark. [From the Cert Agreement: The term Product shall mean an Applicant’s device, equipment, material, or system that has been submitted for testing or evaluation, and found to be in compliance with Intertek Requirements and approved for Listing.
Page 257
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM perform this type of inspection. INITIAL FACTORY AUDIT The purpose of this audit is to ensure the following: The Plant Manager, Foreman and Quality Control Personnel are familiar with this Report. The Plant Quality Control Program will assure that the product is manufactured to the requirements in this Report.
Page 258
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM 2. The equipment used for quality control conforms to the specifications in the quality control procedure. The work area is suitable for a good quality control program. 3.
Page 259
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM ADDITIONAL REQUIREMENTS DRAWING INDEX Intertek ETL Certification Marks Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 354 of 425...
Page 260
Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 6/26/2019 7:45:42 AM INTERTEK ETL CERTIFICATION MARKS Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy Page 355 of 425...