Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/26/2019 7:45:42 AM
TEST REPORT 103536746MTL-002
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103536746MTL-002
Date: 07/13/18
SECTION 8
TEST CALCULATIONS
Weight of test fuel load, dry basis
where:
M
FLdb
M
FLnwb
MC
FLn
n
Weighted Average Determination
where:
Vi
WA
Vi
Vi
LAve
Vi
MAve
Vi
HAve
NOMENCLATURE FOR ASTM E2515:
A
B
ws
C
p
c
r
c
s
E
T
F
p
Version: 05/10/17
Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy
= Σ((M
)(
M
100)⁄(100+MC
Fldb
FLnwb
= weight of test fuel load, dry basis, lb (kg);
= weight of each test fuel piece, n, in test fuel load per 8.4.1, wet basis, lb (kg);
= average fuel moisture of test fuel piece, n, in test fuel load, % dry basis; and
= individual test fuel pieces that comprise the test fuel load, as applicable.
Vi
= 0.4(Vi
)+ 0.4(Vi
WA
LAve)
MAve
= Weighted average for variable i;
= Test result variable (Particulate Matter: g/h, g/kg,
lb/MMBtu; % Overall Efficiency: HHV, LHV;
Carbon Monoxide: g/h, etc.)
= Arithmetic average for variable Vi for all test runs
(except per
8.6.13
or 8.9) that are included in the
low fire burn rate category
= Arithmetic average for variable Vi for all test runs (except per
the medium fire burn rate category;
= Arithmetic average for variable Vi for all test runs (except per 8.9) that are included in the high
fire burn rate category.
= Cross-sectional area of tunnel m2 (ft2).
= Water vapor in the gas stream, proportion by volume (assumed to be 0.02 (2.0 %)).
= Pitot tube coefficient, dimensionless (assigned a value of 0.99).
= Concentration of particulate matter room air, dry basis, corrected to standard
conditions, g/dscm (gr/ dscf) (mg/dscf).
= Concentration of particulate matter in tunnel gas, dry basis, corrected to standard
conditions, g/dscm (gr/dscf) (mg/dscf).
= Total particulate emissions, g.
= Adjustment factor for center of tunnel pitot tube placement.
F
= V
/V
p
strav
scent
(10 OF 21)
ASTM E3053
))
FLn
ASTM E3053
)+ 0.2(Vi
)
HAve
8.6.13
Page 10 of 21
8431 Murphy Drive
Middleton, WI 53562
Telephone: 608-836-4400
Facsimile: 608-831-9279
www.intertek.com/building
or 8.9) that are included in
GFT-OP-10c
Page 336 of 425