1 - INSTALLATION MANUAL SOLUTION 3.5 ENGLISH
4.3.6.4 Maximum Burn Cycle Times
The burn cycle time is the period between loading wood on a coal bed and the consumption of that
wood back to a coal bed of the same size. The flaming phase of the fire lasts for roughly the first
half of the burn cycle and the second half is the coal bed phase during which there is little or no
flame. The length of burn you can expect from your stove, including both the flaming and coal bed
phases, will be affected by a number of things, such as:
firebox size,
the amount of wood loaded,
the species of wood you burn,
the wood moisture content,
the size of the space to be heated,
the climate zone you live in, and
the time of year.
The table below provides a very general indication of the maximum burn cycle times you are likely
to experience, based on firebox volume.
Long burn times are not necessarily an indication of efficient stove operation. When you are home
during the day and able to tend the fire, it is preferable to build a smaller fire that might provide
three or four hours of heating than to fully load the firebox for a much longer burn. Shorter burn
cycles make it easier to match the heat output of the stove to the heat demand of the space.
4.3.6.5 North-South Fires Versus East-West Fires
In fireboxes that are roughly square, wood can be loaded so that looking through the glass door
you see the ends of the logs (north-south) or the sides of the logs (east-west).
East-west loads that are built compactly break down slowly when heated, but the amount of wood
you can load is limited because if you put in too many pieces, one may fall against the glass. East-
west loads are excellent for long, low output fires for relatively mild weather.
North-south loads break down more quickly, but much more wood can be loaded at a time. This
makes north-south loading good for high output, long lasting fires for cold weather.
Solution 3.5 Installation and Operation Manual
Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy
MAXIMUM
FIREBOX VOLUME
BURN TIME
<1.5 cubic feet
3 to 5 hours
1.5 c.f. to 2.0 c.f
5 to 6 hours
2.0 c.f. to 2.5 c.f.
6 to 8 hours
2.5 c.f. to 3.0 c.f.
8 to 9 hours
>3.0 c.f.
9 to 10 hours