Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/26/2019 7:45:42 AM
TEST REPORT 103536746MTL-002
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103536746MTL-002
Date: 07/13/18
Following assembly, the unit was placed on the test stand. Prior to beginning the emissions
tests, the manufacturer operated the unit for a minimum of 50 hours at medium burn rates to
break-in the stove. The unit was found to be operating satisfactory during this break-in. The 50
plus hours of pre-burning were conducted from April 18th to May 14th. The fuel used for the
break-in process was beech cordwood.
Following the pre-burn break-in process the unit was allowed to cool and ash and residue were
removed from the firebox. The unit's chimney system and laboratory dilution tunnels were
cleaned using standard wire brush chimney cleaning equipment. On May 18th 2018, the unit
was set-up for testing.
SECTION 5
EQUIPMENT
Handheld Thermocouple
Thermometer
Floor scale
DGM system 1
DGM System 2
Thermometer calibrator
Reference DGM
10 kg weight
Temperature acquisition
Pitot tube type S
Analytical scale
Table scale
100 mg weight
10 g weight
Anemometer
Magnesense
Magnesense
DGM system 3
Pressure transmitter
Version: 05/10/17
Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy
INV
Equipment
Number
SBI-004
SBI-014
SBI-046
SBI-047
SBI-096
SBI-103
SBI-191
SBI-197
SBI-204
SBI-206
SBI-222
SBI-237
SBI-238
SBI-241
SBI-249
SBI-252
SBI-276
SBI-293
(4 OF 21)
Calibration Due
MU
April 19, 2019
±0.5
March 31, 2019
± 0.022 kg
April 25, 2019
±2% F.S.
April 25, 2019
±2% F.S.
April 05, 2019
±0.5
October 10, 2018
±2% F.S.
April 16, 2019
±0.22 g
June 29, 2018
±0.5
September 05, 2018
±0.003
April 30, 2019
±0.000088 g
March 31, 2019
±0.58 g
July 24, 2018
±0.0017 mg
July 24, 2018
±0.0079 mg
Ocotber 13, 2018
±5.8 ft/min
February 05, 2019
±0.00015" H2O
August 25, 2018
±0.00015" H2O
April 19, 2019
±2% F.S.
June 16, 2018
±9.4e-003 psi
Page 4 of 21
8431 Murphy Drive
Middleton, WI 53562
Telephone: 608-836-4400
Facsimile: 608-831-9279
www.intertek.com/building
o
F
o
F
o
F