Internal Tests In Automatic Cyclic Sequence; Input Circuit Tests; Optional Boards; Cl Board For Courtesy Light - Aprimatic A40M-2 Professional Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SW2 DIP-SWITCHES
S1
S2
S3
S4
FUNCTIONING LOGIC
ON
ON
ON
ON
LS
TRAFFIC LIGHT LOGIC
OFF
ON
ON
ON
UP
DEAD MAN
ON
OFF
ON
ON
D
DIAGNOSTICS
OFF
OFF
ON
ON
SA
WITHOUT CLOSING PREFLASHING
W.OUT PHOTOCELL RESET AND
ON
ON
OFF
ON
A
OPENING WARNING FLASHING
OFF
ON
OFF
ON
A
WITHOUT PHOTOCELL RESET
W.OUT PHOTOCELL RESET AND
ON
OFF
OFF
ON
W
OPENING WARNING FLASHING
OFF
OFF
OFF
ON
W
WITHOUT PHOTOCELL RESET
ON
ON
ON
OFF
A
OPENING PREFLASHING
OFF
ON
ON
OFF
VS
AUTOMATIC FAST
ON
OFF
ON
OFF
W
OPENING PREFLASHING
OFF
OFF
ON
OFF
SA
OPENING PREFLASHING
ON
ON
OFF
OFF
A
AUTOMATIC
OFF
ON
OFF
OFF
IN
INSTALLATION
ON
OFF
OFF
OFF
S
AUTOMATIC SPECIAL
OFF
OFF
OFF
OFF
SA
SEMIAUTOMATIC
SW1 DIP-SWITCHES
PAUSE TIME
S2
S3
S4
(sec.)
ON
ON
ON
2
OFF
ON
ON
5
ON
OFF
ON
10
OFF
OFF
ON
15
ON
ON
OFF
20
OFF
ON
OFF
30
ON
OFF
OFF
60
OFF
OFF
OFF
120
REVERSE
S1
STROKE
ON
YES
OFF
NO
APR02006.TBL
LEAF CLOSING
S5
S6
DELAY (sec)
ON
ON
OFF
ON
ON
OFF
OFF
OFF
LEAF OPENING
S7
S8
DELAY (sec)
ON
ON
OFF
ON
ON
OFF
OFF
OFF
Note: Preflashing is only
possible with the ET2
flashing light.
APR02004.TBL
WORKING
S5
S6
S7
S8
TIME (sec.)
ON
ON
ON
ON
3,5
OFF
ON
ON
ON
4
ON
OFF
ON
ON
6
OFF
OFF
ON
ON
8
ON
ON
OFF
ON
10
OFF
ON
OFF
ON
15
ON
OFF
OFF
ON
20
OFF
OFF
OFF
ON
25
ON
ON
ON
OFF
30
OFF
ON
ON
OFF
35
ON
OFF
ON
OFF
40
OFF
OFF
ON
OFF
45
ON
ON
OFF
OFF
50
OFF
ON
OFF
OFF
60
ON
OFF
OFF
OFF
120
OFF
OFF
OFF
OFF
240

5.2 INTERNAL TESTS IN AUTOMATIC CYCLIC SEQUENCE

The tests carried out in sequence are the following and each one of these controls is
signalled by the lighting up of the relative LED.
a) Motor 1 relay piloting control (L4)
b) Direction relay piloting control (L5)
0
c) Motor 2 relay piloting control (L6)
3,5
d) Pilot light output control (L9)
8
e) Electric lock relay piloting control (L7)
16
At the end of this first phase (lasting approximately 20 sec.), if no problems are found,
the diagnostics LED (L9) flashes for 5 seconds and remains ON, while the system
prepares to carry out tests on the input circuits. If no input is controlled within 50 seconds,
the test starts again from the beginning.
9
6

5.3 INPUT CIRCUIT TESTS

3
To test the input circuits, it is sufficient to activate the input to be tested and check that
0
the microprocessor detects that this input has switched. If the microprocessor receives
APR02005.TBL
the switching signal, the diagnostic LED (L9) flashes for 5 seconds. If, the pulse is not
received by the microprocessor, the diagnostic LED (L9) remains ON to indicate an
input fault.
At the end of the tests, turn OFF the power supply and reprogram the device for the
required logic (type of functioning).
The device has two expansion connectors, called J4 and J5, that can be used to connect
the following optional boards:

• CL board for courtesy light

• SL2 board for beacon ET1 (24 V)
• RA-AS board for leaf opening delay and single leaf
• ES board for one-way traffic light
6.1 CL BOARD FOR COURTESY LIGHT
Functioning
This board is used to command a light up to 100 W with a power of 230 V. Each time the
opening pushbutton is pressed, this light comes ON and remains ON for the entire
opening cycle and for a further 2 and a half minutes. It is also possible to connect more
than one light in parallel, provided that the overall wattage does not exceed 100 W.
Connection method
1. Turn OFF the power supply to the device
2. Fit the board onto connector J4 or J5 matching up the pins
3. Connect the terminal board to two terminals on the CL board, so that the power
supply to the light or lights can be interrupted.