Maintenance; Insert; Glass Door - Empire Comfort Systems Archway 1700 Manuel D'installation Et D'opération

Masquer les pouces Voir aussi pour Archway 1700:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Maintenance

This heater will give many years of reliable service if used and maintained properly. Internal
components of the firebox such as firebricks or refractory panels, baffle and air tubes will
wear over time. Defective parts should always be replaced with original parts see
8: Exploded Diagram and Parts
reloading procedures in section
run with the air intake fully open for entire burn cycles.
6.1

Insert

6.1.1
Cleaning and Painting
Painted and plated surfaces can be wiped down with a soft, damp cloth. If the paint is scratched
or damaged, it is possible to repaint the insert with a heat-resistant paint. Do not clean or
paint the insert when it is hot. Before painting, the surface should be sanded lightly with
sandpaper and then wiped off to remove dust. Apply two thin layers of paint.
6.1.2
Refractory Material and Baffle
Inspect the firebricks or the refractory panels and the baffle for damage periodically and replace
anything that is cracked or broken.
Operation of the heater with a cracked or missing baffle may cause unsafe temperatures
and hazardous conditions and will void the warranty.
6.2

Glass Door

6.2.1
Cleaning
Under normal conditions, the door glass should stay relatively clear. If the firewood is dry
enough and the operating instructions in this manual are followed, a whitish, dusty deposit will
form on the inner surface of the glass after a week or so of use. This is normal and can be easily
removed when the heater is cold by wiping with a damp cloth or paper towel and then drying.
When the insert runs at a low combustion rate, light brown stains may form, especially in the
lower corners of the glass. This indicates that the fire has been smoky and some of the smoke
has condensed on the glass. It also indicates incomplete combustion of the wood, which also
means more smoke emissions and faster formation of creosote in the chimney.
The deposits that form on the glass are the best indication of the fuel quality and success in
properly using the insert. These stains can be cleaned with a special wood insert glass cleaner.
Do not use abrasive products to clean the glass.
The goal should be having a clear glass with no brown stains. If brown stains appear regularly
on the glass, something about the fuel or the operating procedure needs to be changed. When
brown streaks are coming from the edge of the glass, it is time to replace the gasket around the
glass. Always replace the gasket with a genuine one. see
Parts
List».
List». To avoid premature deterioration, follow the lighting and
«5. Burning Wood Efficiently»
Do not clean the glass when the insert is hot.
Do not abuse the glass door by striking or slamming shut.
Do not use the insert if the glass is broken.
and also avoid letting the heater
«Appendix 8: Exploded Diagram and
«Appendix
Page 23

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Wb17in

Table des Matières