Télécharger Imprimer la page
Empire Comfort Systems DV32FP7 Guide Rapide
Empire Comfort Systems DV32FP7 Guide Rapide

Empire Comfort Systems DV32FP7 Guide Rapide

Conversion pour changement de gaz

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Model
DV(D,CD)32FP7
DV(D,CD)36FP7
This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other
qualified agency¹)* in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition)
1
*The term "qualified agency" means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is responsible for (a) the installation
of gas piping or (b) the connection, installation repair, or servicing of equipment, who is
experienced in such work, familiar with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
CHECK SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Switch main switch to "OFF" position. Main burner and pilot should go off.
2. Pilot gas flow should stop within 30 seconds.
3. Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.
Part
Conversion Kit
Description
Pilot Orifice
Main Burner
Orifice
SIT Gas Valve
Conversion Kit
Gas Conversion
Label
Tools Needed: Standard Screwdriver, 1/4" Hex Driver, 5/16" Hex Driver, 3/8" and 7/16" Wrenches
41349-0-1119
All manuals and user guides at all-guides.com
GAS CONVERSION INSTRUCTIONS
DIRECT - VENT GAS FIREPLACE
CONVERSION KITS
Part No.
32880
32882
FOR CONVERSION TO PROPANE GAS
CHECK THE SAFETY SHUTDOWN PERFORMANCE
Conversion Kit
32880
32882
R10426
R10426
P287
P182
R11169
R11169
2139
2139
Empire Comfort Systems Inc. • Belleville, IL
Model
DV(D,CD)42FP7
DVD48FP7
WARNING
WARNING
PARTS LIST
Conversion Kit
31760
R10426
P208
R11169
2139
Conversion Kit
Quantity
31762
Supplied
R10426
P258
R11169
2139
Part No.
31760
31762
1
1
1
1
Page 1

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems DV32FP7

  • Page 1 FOR CONVERSION TO PROPANE GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other qualified agency¹)* in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
  • Page 2 14. Insert Appropriate Propane gas pilot injector orifice into to on card. Also, indicate conversion by adding “Conv.” behind pilot burner using the 5/32" hex wrench. type of gas. 15. Re-install pilot hood to pilot assembly. Push downward to snap in place. Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer.
  • Page 3 31762 POUR CONVERSION AU GAZ PROPANE AVERTISSEMENT Ce nécessaire de conversion doit être installé par un distributeur Empire Comfort Systems Inc. (ou une agence qualifiée )* conformément aux instructions du fabricant et à tous les codes et exigences de l’autorité ayant juridiction. Le défaut de respecter les directives pourrait résulter en de grave blessure ou dégâts matériels.
  • Page 4 14. Insérer l’orifice approprié d’injecteur de veilleuse au gaz ajoutant « Conv. » derrière le type de gaz. propane dans le brûleur de la veilleuse à l’aide d’une clé hexagonale de 5/32 po. Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez communiquer avec votre revendeur. www.empirecomfort.com Page 4 Empire Comfort Systems Inc. • Belleville, IL 41349-0-1119...

Ce manuel est également adapté pour:

Dvd32fp7Dvcd32fp7Dv36fp7Dvd36fp7Dvcd36fp7Dv42fp7 ... Afficher tout