Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 4/30/2018 7:18:14 AM
Test report 103328128MTL-001 (9 of 18)
Stove Builder International Inc.
Project No. G103328128

RUN #4 Medium burn rate

Note: For this test run, according to WK47329-14, the sampling starts as soon as the kindling is ignited (cold start).
Stove lighting: 6.5 lbs
Split the start-up fuel log into 6 pieces. Crisscross the 6 pieces on the brick, leaving some space between each
wood piece. Crisscross the kindling on the top of the start-up fuel. The kindling is made of between 8-10 twigs that
are 10% of moisture content. Place crumbled newspaper on top kindling (5 full sheets). Light up the paper and let
the door ajar to leave a space of one inch on the door handle's side for five minutes, then close the door. The fan is
always OFF.
High burn: 14 lbs
When there is coal bed of 1.5 lb left, break ashes and level coal bed, then add pre-load in an East-West
configuration divided in 2 columns: 2 logs in the back and 2 logs in the front. Leave one inch of air space between
the columns. Let the door ajar to leave a space of one inch on the door handle's side for five minutes. Close the
door. Start the fan at full speed.
II.D
SUMMARY OF OTHER DATA
TABLE 1 - EMISSIONS
Run
Test
Number
Date
27
1
Nov
2017
28
2
Nov
2017
29
3
Nov
2017
30
4
Nov
2017
Stove Builder International Inc. | 43615 | Rev: Apr 27 2018 2:35PM | Uncontrolled Copy
Particulate
Burn Rates
Emission
(kg/hr)(Dry)
Rate
(g/hr)
1.149
1.065
2.254
1.817
1.103
0.736
1.346
1.639
Date: December 27, 2017
st
1
Hour
CO
Emissions
Emissions
Emissions
(g)
(g/hr)
5.14
54
4.30
60
3.75
51
5.86
69
Page 9 of 18
CO
Heating
Efficiency
(g/min)
(% HHV)
0.9
72
1.0
67
0.8
71
1.1
68
Page 162 of 195