Télécharger Imprimer la page

Reset To Factory Default Settings - Axis A1001 Guide D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. Optionally, in the ID field under Door position sensor: Enter the six-character-long
address of the device that you want to add. The device address is printed on the product
label.
7. Click Add.
Prerequisites SmartIntego
The following prerequisites needs to be met before proceeding with the SmartIntego configuration:
A csv-file needs to be created. The csv-file contains information about what
GatewayNode and doors that are used in your SmartIntego solution. The file is created in
a standalone software provided by a SimonsVoss partner.
The Hardware Configuration of SmartIntego has been done, see How to create a new
hardware configuration for wireless locks on page 43.
Note
• SmartIntego Configuration tool must be version 2.1.6452.23485,
build 2.1.6452.23485 (8/31/2017 1:02:50 PM) or later.
• The Advanced Encryption Standard (AES) is not supported for SmartIntego, and must
therefore be disabled in the SmartIntego Configuration tool.
How To Configure SmartIntego
Note
• Make sure that prerequisites listed have been met.
• For increased visibility of the battery status, go to Setup > Configure event and alarms
logs, and add either Door — Battery alarm or IdPoint — Battery alarm as an alarm.
• The door monitor settings come from the imported CSV file. You shouldn't need to change
this setting in a normal installation.
1. Click Browse..., select the csv-file and click Upload file.
2. Select a GatewayNode and click Next.
3. A preview of the new configuration is shown. Disable the door monitors if needed.
4. Click Configure.
5. An overview of the doors included in the configuration is shown. Click Settings to
configure each door individually.

Reset to factory default settings

Important
Reset to factory default should be used with caution. A reset to factory default resets all
settings, including the IP address, to the factory default values.
To reset the product to the factory default settings:
AXIS A1001 Network Door Controller
45
EN

Publicité

Chapitres

loading