5.6 Set Scale's ID

Set the scale's ID by following these instructions:
1.
2.

5.7 Displayed Messages

Below are the screen messages you may see during operation of this scale and what
they mean.
Err01
– – – – – –
Err03
Err04
Err05
Err12
CAL.Err
Err30
Err31
CAP
UoL
Add
PC.t
SPL.PCS
uP.PCS
Lo.PCS
unLd
InP.Ld
CAL.oN
CAL.oFF
DSP.OVR
28
In normal working mode, hold the ON/OFF and PLU6 keys at the same time
until ...
SEtUP is displayed in the PIECE WEIGHT window.
id (ID) is displayed in the COUNT window.
xxxxxx is displayed in the WEIGHT window. This means that the scale's
ID is currently set to xxxxx.
Use the numeric keys to change the scale's ID and press the Enter key save
the setting ...
The scale returns to normal mode.
Scale overloaded
Too many accumulations or accumulated counts too high
Weight signal is too small
The zero point is too high
The zero point is too low
The setting parameter(s) is not in normal range, or the parameter
has not been set
There is an error in calibration: maybe the loaded weight is too
small or the input weight is not correct.
Input signal of ADC is over max. range
Input signal of ADC is below min. range
Displaying data relating to capacity
Displaying data relating to voltage
The accumulated data
Data about piece weight
Data about sample pieces
Data about upper limit pieces
Data about lower limit pieces
Unload weight on the platter
Input loaded weight's number
Calibration enable switch is ON
Calibration enable switch is OFF
Displayed data is over 999999 or down -99999 (not include
decimal point)
B140 Counting Scale User Instructions