5.3 View Voltage and A/D Counts

You can view the battery voltage and A to D counts for diagnostic purposes. Follow
these steps:
1.
2.

5.4 Set RS232 Parameters

You can set the following RS232 parameters: Baud rate, Byte Format and when the
content will be output. Follow these steps:
1.
2.
26
With the calibration switch in the normal weighing mode and the scale in normal
mode, press and hold the On/Off and PLU3 keys at the same time until the
scale beeps ...
Vol. X.X is displayed in the PIECE WEIGHT window. Vol. stands for
voltage and X.X is the current voltage of the battery. If no battery is
installed or the connection is not complete, Vol. 7.2-7.3 will be displayed.
CodE is displayed in the COUNT window.
A to D counts (code) is displayed in the WEIGHT window.
When the current working voltage is lower than 5.7V, Lo.Bat will shown
in the WEIGHT window.
When the voltage is lower than 5.5V, Lo.Bat will shown in the WEIGHT
window and the beeper will sound for approximately two minutes before
the scale turns itself off.
The A to D counts for an empty scale should be between 5000 and
100,000. This should be a positive number. The A to D counts for a scale
at full capacity should be above 300,000. If the A to D counts are outside
of these ranges or calibration and normal weighing cannot be done you
scale's loadcell has been permanently damaged.
To exit this mode, press the ON/OFF key ...
The scale will restart and returns to normal mode.
In normal mode, press and hold the ON/OFF and PLU4 keys at the same time
until ...
SEtUP is displayed in the PIECE WEIGHT window.
232.bps (RS232 Baud rate) is displayed in the COUNT window
xxxx (xxxxx = 1200-2400-4800-9600-19200) is displayed in the
WEIGHT window. This means that the RS232 baud rate is currently set
to xxxxx.
Press the 1, 2, 3, 4 or 5 numerical key to change the baud rate (Default setting:
9600). When the desired baud rate is displayed, press the Enter key to save
the setting ...
232.dFt (RS232 byte format) is displayed in the COUNT window.
xxx (xxx = 8N1, 7E1 or 7O1) is displayed in the WEIGHT window. This
means that the RS232 byte format is currently set to xxx.
B140 Counting Scale User Instructions