The indicated percentage displays the alternator's state of health :
Between 0 and a 100%
At a 100%
Between a 100% and 200%
PROTECTION
These clamps have been designed for maximum protection :
• The charging clamps are fully insulated.
• A fuse guarantees protection against polarity inversion and short circuits. Replacing it requires manual intervention.
• The thermal protection is monitored by a thermostat (cooling for approximately 1/4h). The fault indicator switches
on, the display shows «th».
• If the machine is faulty, an extra thermal protection cuts the machine's power supply without further indications for
the user. Place the machine in a well ventilated area and wait 15 minutes.
• In the event of power supply fault, the machine will enter fault protection mode, The error LED switches on and the
display shows «dEF». If the fault is major, an internal fuse protects the machine. This fuse must be replaced by an
aftersales technician.
TROUBLESHOOTING
Remedies
Error LED flashes
Error LED flashes and alarm beep
The LEDs won't light up
In START ENGINE mode, if the screen displays
0%. Restart impossible.
Battery is boiling.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
18
DIAG-STARTIUM 60-12 / 60-24
Undercharge fault, the battery is not correctly charged.
Alternator all good.
Overcharge fault.
DIAG-STARTIUM 60-12/60-24
Causes
Power supply issue.
Clamps in short-circuit or polarity reversal.
The battery is faulty.
Voltage error (6V-12V-24V)
Battery not detected or <1V. Display : «BAt
HS»
After intensive use the device goes to thermal
protection. Display : «th»
Power supply issue.
The internal fuse is melt.
The ON/OFF switch is not engaged.
The battery is sulphated, start is avoided to
protect the vehicle electronics.
The voltage selected 12 or 24V is not correct.
The battery has element in short-circuit.
Remedies
Check the power supply.
Check if the fuses have blown.
Do not put the clamps in short-circuit. Reverse
the polarity.
Check the voltage at the battery terminals with
a voltmeter. If the voltage instantaneously
increase by more than 2.5V by element the
battery can be sulphated or damaged.
Check if the battery is correctly connected
either in 6V, 12V or 24V.
Connect the battery.
Select TIMER if the battery voltage is <1V.
Wait 1/4h for the device to cool down.
Check the power supply.
Send the device back to GYS after sales.
Switch the ON/OFF button.
Recharge the battery prior using START
ENGINE.
Check the battery voltage and connect it
following the recommended connection.
The battery cannot be recovered, it must be
replaced.