6.1.3
EXTERNAL INPUT FUNCTION SELECTION
INPUT
CLEAR
CHANNE.
CONFIG
OUTPUT
EXT. IN.
SERVIC.
KEYS
!
Response time to the change of input is
approx 100 ms
EXT. 1
OFF
LOCK. K.
HOLD
DEF
TARE
CLEAR
CLR. ST.
CL. SUM.
SUMA
COUNT.
FREQ.
CONFIGURATION PROFI
EXT. IN.
External input function
selection
OFF
Input is off
LOCK. K.
Auxiliary input governs the
„LOCK" function
- the input governs the blocking of control keys
on front panel
HOLD
Auxiliary input governs the
„HOLD" function
- the input governs the HOLD function, which
blocks all instrument functions
TARE
Auxiliary input governs the
„TARE" function
- the TARE function is activated through the
input, only in the "Frequency" mode
CLEAR
Auxiliary input governs the
„Clear" function
- stopwatch/counter is cleared (preset) through
the input
CLR. St.
Auxiliary input governs the
„Clear" function
- stopwatch/counter is cleared (preset) through
the input, Stopwatcg stops altogether
CL. SUM.
Auxiliary input governs the
„Clear Sum" function"
- the "grand total" of the counter is zeroed
SUMA
Auxiliary input governs the
„SUM" function
- the cummulated value is displayed
COUNT.
Auxiliary input governs the
counter display
- the value of "Counter" channel is displayed
FREQ.
Auxiliary input governs the
frequency display
- the value of "Frequency" channel is displayed
MODE D'EMPLOI OM 653UQC | 45