8.1

Clearances

APPLIANCE CLEARANCES
WITH SINGLE WALL PIPE
CONNECTOR
Canada
A
17" (432 mm)
B
12" (305 mm)
C
12" (305 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
CONNECTOR WITH SINGLE
WALL PIPE CONNECTOR
Canada
D
20 ½" (521 mm)
E
21" (533 mm)
F
20 ¾" (527 mm)
8.1.1
With Heat Shield AC02710
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use
of a heat shield certified with the single wall pipe connector to be used as close as 6" from
combustible materials must be used. Only in this case, the same clearances as a certified
double wall pipe connector can be used.
APPLIANCE CLEARANCES
WITH DOUBLE WALL PIPE
CONNECTOR
Canada
A
2 ½" (64 mm)
B
2 ½" (64 mm)
C
2 ½" (64 mm)
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
1
mentioned.
USA
17" (432 mm)
12" (305 mm)
12" (305 mm)
FROM PIPE
1
USA
20 ½" (521 mm)
21" (533 mm)
20 ¾" (527 mm)
USA
2 ½" (64 mm)
2 ½" (64 mm)
2 ½" (64 mm)
APPLIANCE CLEARANCES
WITH DOUBLE WALL PIPE
CONNECTOR
Canada
A
9" (229 mm)
B
12" (305 mm)
C
12" (305 mm)
DISTANCES
CONNECTOR WITH DOUBLE
WALL PIPE CONNECTOR
Canada
D
12 ½" (318 mm)
E
21" (533 mm)
F
20 ¾" (527 mm)
DISTANCES1 FROM DOUBLE
WALL PIPE CONNECTOR
Canada
D
6" (152 mm)
E
11 ½" (292 mm)
F
11 ¼" (286 mm)
USA
9" (229 mm)
12" (305 mm)
12" (305 mm)
FROM PIPE
1
USA
12 ½" (318 mm)
21" (533 mm)
20 ¾" (527 mm)
USA
6" (152 mm)
11 ½" (292 mm)
11 ¼" (286 mm)