Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 4/30/2018 7:18:14 AM
Test report 103328128MTL-001 (4 of 18)
Stove Builder International Inc.
Project No. G103328128
I.

INTRODUCTION

Intertek Testing Services NA (Intertek) has conducted testing for Stove Builder
International Inc., on model 1.7 Series Wood Burning Room Heater to evaluate all
applicable performance requirements included in "Determination of particulate matter
emissions from wood heaters."
I.A
PURPOSE OF TEST
The test program was conducted to determine if the unit is in accordance with U.S. EPA
requirements under EPA 40 CFR Part 60 "Standards of Performance for New
Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air
Furnaces". This evaluation was conducted from November 27
The following test methods were applicable:
I.B
LABORATORY
The tests on the model 1.7 Series Wood Burning Heater were conducted at the client
facility in St-Augustin-de-Desmaures, Quebec located at 250 de Copenhague, St-
Augustin-de-Desmaures, Quebec, Canada G3A 2H3. The laboratory elevation is 213
feet above sea level. The test was conducted by Claude Pelland, P.E. and observed by
Guillaume Thibodeau-Fortin of Stove Builder International Inc.
I.C
DESCRIPTION OF UNIT
The model 1.7 Series Wood Fuel Room Heater is constructed of sheet steel. The outer
dimensions are 23 19/32-inches deep, 29 3/8-inches high, and 22 1/2-inches wide. The
unit has a door located on the front with a viewing glass.
Proprietary drawings and manufacturing methods are on file at Intertek at 1829, 32nd
Avenue Montreal (Lachine), QC Canada H8T 3J1
Stove Builder International Inc. | 43615 | Rev: Apr 27 2018 2:35PM | Uncontrolled Copy
ASTM E2515-11- Standard Test Method for Determination of Particulate Matter
Emissions Collected by a Dilution Tunnel
WK47329-14 - Standard Test Method for Determining Particulate Matter
Emissions from Wood Heaters using Cordwood Test Fuel. It is based on the
ATM send by EPA on October 12
CSA B415.1-10 - Performance Testing of Solid-Fuel-Burning Heating Appliances
Date: December 27, 2017
th
to November 30
th
, 2017.
(See product drawings.)