Ii.ddescription Of Test Runs; Run #1 Low Burn Rate; Run #2 High Burn Rate - Empire Comfort Systems Gateway 1700 Mode D'emploi

Masquer les pouces Voir aussi pour Gateway 1700:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 4/30/2018 7:18:14 AM
Test report 103328128MTL-001 (7 of 18)
Stove Builder International Inc.
Project No. G103328128
II.D
DESCRIPTION OF TEST RUNS

RUN #1 Low burn rate

Stove lighting: 6.5 lbs
Split the start-up fuel log into 6 pieces. Crisscross the 6 pieces on the brick, leaving some space between each
wood pieces. Crisscross the kindling on the top of the start-up fuel. The kindling is made of between 8-10 twigs
that are 10% of moisture content. Place crumbled newspaper on top kindling (5 full sheets). Light up the paper and
let the door ajar to leave a space of one inch on the door handle's side for five minutes, then close the door. The
fan is always OFF. Kindling adjustment at 11 minutes
Pre-load (high burn): 14 lbs
When there is coal bed of 1.5 lb left, break ashes and level coal bed, then add pre-load in an East-West
configuration divided in 2 columns: 2 logs in the back and 2 logs in the front. Leave one inch of air space between
the columns. Let the door ajar to leave a space of one inch on the door handle's side for five minutes. Close the
door and let burn until the weight is down to target.
Close the primary air control at the minimum when there is 3 lb remaining. When the average stove temperature
gets to 305°F, stir the coal bed. Let the door ajar by one inch for one minute. There should be approximately 2 lb of
coal bed and the average temperature should be around 300°F.
Loading: 17.5 lbs
For the loading, put 1 log at the back, 2 in the center and 2 in the front. The distance between the logs shall be
approximately 0.5 inch. Let the door ajar for 6 minutes and then close the door with the primary air control open.
Close the primary air control at 16 minutes or when 15% of the load weight has been consumed, whichever comes
first. Start the fan at minimum speed at 30 minutes.

RUN #2 High burn rate

Stove lighting: 6.5 lbs
Split the start-up fuel log into 6 pieces. Crisscross the 6 pieces on the brick, leaving some space between each
wood piece. Crisscross the kindling on the top of the start-up fuel. The kindling is made of between 8-10 twigs that
are 10% of moisture content. Place crumbled newspaper on top kindling (5 full sheets). Light up the paper and let
the door ajar to leave a space of one inch on the door handle's side for five minutes, then close the door. The fan is
always OFF. Kindling adjustment at 13 min.
Stove Builder International Inc. | 43615 | Rev: Apr 27 2018 2:35PM | Uncontrolled Copy
Date: December 27, 2017
Page 7 of 18