OPTIONAL:
if you connect the brown and black wires to the
control relays on your boiler, it will be switched off if the water
level rises too high in the unit.
ATTENTION:
The maximum current admissible for our
detection system is 0.5A.
To protect the electrical components in the
®
SANICONDENS
Plus, once the alarm has been triggered,
any water continuing to fill the tank comes out through the
overflow outlets in the cover.
7e
EXAMPLE OF AN INSTALLATION OF
A SANICONDENS
®
Plus: see fig.
8
STANDARDS
SANICONDENS
®
Plus conforms to the European directive
89/336/CEE on electrical safety.
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
9
DISASSEMBLY
If a breakdown occurs, any service on the unit should be
carried out by a qualified engineer. In particular the
replacement of the power cable.
Disconnect the electrical supply before carrying out
work on the unit.
7e
1 0
TROUBLESHOOTING
INSTRUCTIONS RESERVED SOLELY FOR
QUALIFIED PROFESSIONALS
Disconnect the electrical supply before carrying out any work.
FAULT DETECTED
PROBABLE CAUSES
• The pump does not start
• The pump is not
connected to the power
supply
• Power cut
• Float blocked
• Condensates inlet pipe
blocked
• The pump does not lift
• Non-return valve blocked
• Discharge pipe blocked
1 1
GUARANTEE
®
SANICONDENS
Plus SFA is guaranteed for 2 years for
parts and labour, subject to correct installation and use of
the unit.
ACTION NEEDED
• Plug in the unit.
• Check the mains voltage.
• Clean the SANICONDENS
®
Plus tank.
• Clean the SANICONDENS
®
Plus inlet pipe.
• Clean the valve.
• Clean the discharge pipe.