Betriebsanleitung
Explosionsgeschützte Steuergeräte
GHG 411 und GHG 412
Operating instructions
Explosion-protected control units
GHG 411 and GHG 412
Mode d'emploi
Boites de commande GHG 411 et GHG 412
pour atmosphères explosives
GHG 410 7001 P0001 D/E/F (I)

Publicité

Table des Matières
loading

Sommaire des Matières pour Cooper Crouse-Hinds GHG 411

  • Page 1 Betriebsanleitung Explosionsgeschützte Steuergeräte GHG 411 und GHG 412 Operating instructions Explosion-protected control units GHG 411 and GHG 412 Mode d’emploi Boites de commande GHG 411 et GHG 412 pour atmosphères explosives GHG 410 7001 P0001 D/E/F (I)
  • Page 2: Table Des Matières

    Explosionsgeschützte Explosion-protected control Boites de commande Steuergeräte GHG 411 und units GHG 411 and GHG 412 GHG 411 et GHG 412 pour GHG 412 atmosphères explosives Inhalt: Contents: Contenu: Inhalt ........2 Contents ........ 2 Contenu ......... 2 Maßbilder ......3-5 Dimensional drawings ...
  • Page 3: Maßbilder

    Explosionsgeschützte Steuergeräte GHG 411 / 412 Technische Angaben Maßbilder in mm Komplette Steuergeräte Gerätekennzeichnung nach 94/9/EG: II 2 G II 2 D T 48°C Explosionsschutz: EEx e II T6 / EEx e ib II C T6 EEx ed II C T6 / EEx ed ib IIC T6 EG-Baumusterprüfbescheinigung:...
  • Page 4: Eigensichere Stromkreise

    Explosionsgeschützte Steuergeräte GHG 411 / 412 Messinstrument AM45/AM72 Maßbilder Bedienelemente EG-Baumusterprüfbescheinigung: PTB 99 ATEX 2032 U Messwerk: Dreheisen EEx e Drehspule EEx ib II C Genauigkeit: Klasse 2,5 Klasse 1,5 Überlastbereich: 10-fach - 25 sek. 10-fach - 5 sek. 25-fach - 4 sek.
  • Page 5: Verwendungsbereich

    Eigenschaften Eigenschaften Eigenschaften Eigenschaften Installation Maßbilder Bedienelemente Die Steuergeräte GHG 411 und GHG 412 Für das Errichten / Betreiben sind die relevan- dienen zur Vor-Ort-Steuerung elektrischer ten nationalen Vorschriften (z.B. Betr.Si.V, Anlagen in explosionsgefährdeten Bereichen. Gerätesicherheitsgesetz in Deutschland) sowie Diese Geräte sind, abhängig vom Einzelfall, je...
  • Page 6: Kabel-Und Leitungs-

    Explosionsgeschützte Steuergeräte GHG 411 / 412 Die ordnungsgemäß abisolierten Anschluss- Kabel-und Leitungs- Schaltabwicklungen leitungen der Kabel sind unter Berücksichti- einführungen (KLE); gung einschlägiger Vorschriften anzuschließen. Verschlussstopfen Bei der Verwendung von mehr- oder fein- drähtigen Anschlusskabel /-leitungen sind die Aderenden entsprechend den geltenden natio- Es dürfen generell nur bescheinigte KLE´s...
  • Page 7: Schließen Des Gerätes

    Explosionsgeschützte Steuergeräte GHG 411 / 412 Schließen des Gerätes / Die erforderlichen Wartungsintervalle sind Befestigungslöcher auf Gerätehalter Größe 1 anwendungsspezifisch und daher in Abhän- Deckelverschluss Gerätehalter für Gitterrinnen- und Wand- gigkeit von den Einsatzbedingungen vom befestigung Betreiber festzulegen. Beim Aufsetzen der Gehäusedeckel ist darauf zu achten, dass die Vorsätze korrekt...
  • Page 8: Technical Data

    Explosion-protected control units GHG 411 / 412 Technical data Dimensions in mm Control unit assemblies Marking acc. to 94/9/EC: II 2 G II 2 D T 48°C Explosion category: EEx e II T6 / EEx e ib II C T6...
  • Page 9: Am45/Am72 Measuring Instrument

    Explosion-protected control units GHG 411 / 412 AM45/AM72 measuring instrument: Dimensions of actuator elements EC type examination certificate: PTB 99 ATEX 2032 U Movement: Moving iron EEx e Moving coil EEx ib II C Measuring accuracy: Class 2.5 Class 1.5 Overload range: 10-fold at 25 sec.
  • Page 10: Field Of Application

    0.6 W resistors, fine-wire fuses and diodes (max. power dissipation 1 W). The control units GHG 411 and GHG 412 are suited for mounting on CEAG apparatus The measuring instruments are used for the holders by means of self-cutting screws (see local indication of electrical values.
  • Page 11: Blanking Plug

    Explosion-protected control units GHG 411 / 412 The properly bared conductors of cables shall Cable entries (KLE); Cable entries (KLE); Cable entries (KLE); Cable entries (KLE); Cable entries (KLE); Contact arrangements be connected with due regard to the blanking plugs...
  • Page 12: Closing Apparatus

    Explosion-protected control units GHG 411 / 412 Closing apparatus / Prior to opening the enclosure, it is Fastening holes of the apparatus mounting necessary to ensure that the voltage supply Cover closure plates size 1 has been isolated or to take suitable Apparatus mounting plate for channel- and protective measures.
  • Page 13: Caractéristiques Techniques

    Boites de commande GHG 411 / 412 pour atmosphères explosives Caractéristiques techniques Dimensions en mm Boites de commande complete Marquage selon 94/9/CE: II 2 G II 2D T 48°C Mode de protection: EEx e II T6 / EEx e ib II C T6...
  • Page 14: Instrument De Mesure Am

    Boites de commande GHG 411 / 412 pour atmosphères explosives Instrument de mesure AM45/AM72 Dimensions des elements de commande Attestation d’examen CE de type: PTB 99 ATEX 2032 U Mécanisme de mesure: ferromagnétique magnéto-électrique EEx e EEx ib II C...
  • Page 15: Domaine D'utilisation

    Boites de commande GHG 411 / 412 pour atmosphères explosives Utilisation / Propriétés Installation Dimensions des elements de commande Les boites de commande GHG 411 et Pour l’installation et l’exploitation de ces GHG 412 servent à la commande sur place appareils, la règlementation nationale en vigueur...
  • Page 16: Entrées De Câble (Kle) Bouchons De Fermeture

    Boites de commande GHG 411 / 412 pour atmosphères explosives En tenant compte des règlements respectifs, Entrées de câble (KLE) / Schémas des connexions les conducteurs dûment dénudés des câbles Bouchons de fermeture sont raccordés. Généralement, seuls des bouchons de En cas d’utilisation de câbles de connexion...
  • Page 17: Mise En Service

    Boites de commande GHG 411 / 412 pour atmosphères explosives Fermetur Fermetur Fermetur Fermetur Fermeture de l’appar e de l’appar e de l’appar e de l’appareil / e de l’appar eil / eil / eil / eil / Les intervalles de service requis dépendent de Trous de fixation sur porte-appareils taille 1 l’emploi spécifique et devront donc être fixés...
  • Page 18 COOPER Crouse-Hinds GmbH...
  • Page 19 COOPER Crouse-Hinds GmbH...
  • Page 20 EU:n gebruiksinstructie in een andere kielellä Teidän COOPER Crouse- EU-taal worden opgevraagd bij Uw Hinds - edustajaltanne" COOPER Crouse-Hinds - vertegenwoordiging" Εαν χρειασθει, µεταϕραση των "En översättning av denna ο δ η γ ι ω ν...