Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Betriebsanleitung
Operating instructions
Mode d'emploi
Explosionsgeschützte Verteilungen
GHG 619
Explosion-protected distributions
GHG 619
Tableaux de distribution pour atmosphères explosives
GHG 619
GHG 610 7002 P0001 D/E/F (p)
CROUSE-HINDS
SERIES

Publicité

Table des Matières
loading

Sommaire des Matières pour Cooper Crouse-Hinds EATON GHG 619

  • Page 1 Betriebsanleitung CROUSE-HINDS Operating instructions SERIES Mode d’emploi Explosionsgeschützte Verteilungen GHG 619 Explosion-protected distributions GHG 619 Tableaux de distribution pour atmosphères explosives GHG 619 GHG 610 7002 P0001 D/E/F (p)
  • Page 2: Table Des Matières

    Explosionsgeschützte Explosion-protected distributions Tableaux de distribution GHG 619, Verteilungen GHG 619 GHG 619 pour atmosphères explosives Inhalt Contents Contenu Technische Angaben ����������������������������������������3 Technical Data �����������������������������������������������26 Caracteristiques techniques ���������������������������48 1�1 Komplette Verteilung ��������������������������������������� 3 1�1 Complete distribution ������������������������������������ 26 1�1 Tableaux de distribution complet ������������������� 48 1�2 Sammelschienensystem bis max�...
  • Page 3: Technische Angaben

    Explosionsgeschützte Verteilungen GHG 619 Technische Angaben Komplette Verteilung EG-Baumusterprüfbescheinigung: PTB 99 ATEX 1044 Gerätekennzeichnung nach 94/9/EG und Norm: EN 60079-0 D II 2 G Ex d e ia/ib m [ia/ib] IIC (IIB)T6/T5/T4 D II 2 D Ex tD A21 IP66/IP65 T80°C, T95°C eingeschränktes Sortiment IECEx Konformitätsbescheinigung: IECEx BKI 06.0007...
  • Page 4: Sammelschienensystem Bis Max. 180 A

    Explosionsgeschützte Verteilungen GHG 619 Sammelschienensystem bis max. 180 A Bild 1 Anschlussbilder EG-Baumusterprüfbescheinigung: PTB 99 ATEX 1044 Explosionsschutz: Ex e II Bemessungsspannung: bis 730 V AC Anschluss Bemessungsstrom: max. 180 A bis 35 mm² Kurzschlussstrom: max. 47 kA Vorsicherung: max. 250 A gL Bemessungskurzzeitstrom (1s): 1378 A Anschlussquerschnitt:...
  • Page 5: Leistungsschalter 1-, 2-, 3-, 4-Polig Ghg 61

    Explosionsgeschützte Verteilungen GHG 619 Bild 1.3.a Anschluss Haupt-; 1.3a Leistungsschalter 1-, 2-, 3-, 4-polig GHG 61 Hilfs-/Signalkontakte EG-Baumusterprüfbescheinigung: PTB 98 ATEX 1087U Explosionsschutz: Ex de II C Temperaturbereich: einsetzbar in Temperaturklassen T4 - T6 Hauptkontakt Hilfskontakt Bemessungsspannung: bis 400V AC bis 240V AC Maximalspannung gem.
  • Page 6: Fi - Schutzschalter 2- Und 4-Polig Ghg61

    Explosionsgeschützte Verteilungen GHG 619 FI - Schutzschalter 2- und 4-polig GHG61 Bild 1.4 Anschluss Hauptkontakte EG-Baumusterprüfbescheinigung: PTB 98 ATEX 1087U Explosionsschutz: Ex de II C Temperaturbereich: einsetzbar in Temperaturklassen T4 - T6 Hauptkontakt Hilfskontakte Bemessungsspannung: bis 440 V AC bis 250 V AC Hauptkontakt Hilfskontakt Bemessungsstrom:...
  • Page 7: Fi - Schutzschalter 2- Und 4-Polig; Ghg624

    Explosionsgeschützte Verteilungen GHG 619 FI - Schutzschalter 2- und 4-polig; GHG624 Bild 1.5 FI Prüftaste Bemessungsspannung: Hauptkontakt 230/400 V AC bis 240/415 V AC Hilfskontakte bis 230 V AC "TEST" Bemessungsstrom: Hauptkontakt bis 63 A Pos. 1 Hilfskontakt max. 5 A Kurzschlussfestigkeit: 10 kA Vorsicherung:...
  • Page 8 Explosionsgeschützte Verteilungen GHG 619 Anschlussbilder 1.5.b.1 Signalkontakt GHG 62 Zusatzeinrichtungen Bemessungsspannung: bis 230 V Bemessungsstrom: Minimaler Bemessungsstrom: 5 mA bei 24 V Ein-/Ausschaltvermögen I (EN62019): Signalkontakt AC 14 1 A / 400 V 2 A / 230 V DC 12 1 A / 220 V 1,5 A / 110 V DC 13...
  • Page 9: Stromstoßschalter

    Explosionsgeschützte Verteilungen GHG 619 Stromstoßschalter Anschlussbilder EG-Baumusterprüfbescheinigung: PTB 98 ATEX 1087U Explosionsschutz: Ex de II C Temperaturbereich: einsetzbar in Temperaturklassen T4 - T6 Bemessungsspannung: bis 400 V AC 8 V bis 275 V* AC 8 V bis 220 V DC Betätigungsspannung: *Andere Spannungen sind auf Anfrage möglich Bemessungsstrom:...
  • Page 10: Installationsschütz 40A

    Explosionsgeschützte Verteilungen GHG 619 Installationsschütz 40A Anschlussbilder EG-Baumusterprüfbescheinigung: PTB 98 ATEX 1087U Explosionsschutz: Ex de II C Temperaturbereich: einsetzbar in Temperaturklassen T4 - T6 Bemessungsspannung: bis 400 V AC Hauptkontakte Hilfskontakte 24 V bis 275 V* AC Steuerspannung: (*Andere Spannungen sind auf Anfrage möglich) Bemessungsstrom: Hauptkontakte Schließer - bis 40 A Öffner - bis 32 A...
  • Page 11: Überspannungsableiter

    Explosionsgeschützte Verteilungen GHG 619 1.12 Überspannungsableiter Anschlussbilder EG-Baumusterprüfbescheinigung: PTB 98 ATEX 1087U Explosionsschutz: Ex de II C Temperaturbereich: einsetzbar in Temperaturklassen T4 - T6 Netzbetriebsspannung: max. 275 V AC Nennableitstoßstrom I max. 5 kA Grenzableitstrom I max. 25 kA Ansprechzeit t 25 ns Restspannung bei Netzbetriebsspannung: ca.
  • Page 12: Thermisches Überstromrelais

    Explosionsgeschützte Verteilungen GHG 619 1.15 Thermisches Überstromrelais Anschlussbilder EG-Baumusterprüfbescheinigung: PTB 98 ATEX 1087U Explosionsschutz: Ex de II C Temperaturbereich: einsetzbar in Temperaturklassen T4 - T6 Bemessungsspannung: bis 690 V AC bis 275 V* AC Steuerspannung: (*Andere Spannungen sind auf Anfrage möglich) Dauerbetriebsstrom I Auslösestrom: 0,16 A ..
  • Page 13: Motorschutzschalter Bis 25 A

    Explosionsgeschützte Verteilungen GHG 619 1.18 Motorschutzschalter bis 25 A Maßbilder EG-Baumusterprüfbescheinigung: PTB 99 ATEX 1007U Maßangaben in mm Explosionsschutz: Ex de II C Temperaturbereich: einsetzbar in Temperaturklassen T5 -T6 Motorschutzschalter Bemessungsspannung: 690 V, 50/60 Hz / 440 V DC Bemessungsstrom: bis 25 A 500 V AC 690 V AC...
  • Page 14: Bedienklappe

    Explosionsgeschützte Verteilungen GHG 619 1.19 Bedienklappe Maßbilder EG-Baumusterprüfbescheinigung: PTB 99 ATEX 3107U Maßangaben in mm Explosionsschutz: Ex e II Bedienklappe Gewicht Klappe Größe 1: ca. 0,48 kg Gewicht Klappe Größe 2: ca. 0,78 kg Klappe Größe 1 für GHG 61 Klappe Größe 2 für GHG 61 Rastrahmen Größe 2 für GHG 61 Klappe Größe 1 für GHG 62...
  • Page 15: 1.21 Sockel Allgemein

    Explosionsgeschützte Verteilungen GHG 619 1.21 Sockel allgemein ATEX EG-Baumusterprüfbescheinigung: IBExU14ATEX1030U Gerätekennzeichnung nach 94/9/EG und Norm: EN 60079-0 II 2 G Ex d e IIC/IIB Gb I M 2 Ex d e I Mb IECEx Konformitätsbescheinigung: IECEx IBE 14.0005U Gerätekennzeichnung: IEC60079-0 Ex d e IIC/IIB Gb Ex d e I Mb 1.21.1 Drucktastersockel 2 polig für...
  • Page 16 Explosionsgeschützte Verteilungen GHG 619 Maßbilder Bedien- und Anzeigeelemente Anschlussbilder Maßangaben in mm 2 Ö 1 S+1 Ö Drucktaster- Doppeldrucktaster- vorsatz vorsatz 2 Ö 1 S+1 Ö Schlüsselschaltervorsatz Schlüsseltastervorsatz Schaltung .061 6060 .063 6062 .067 6065 Schaltwerk Schaltervorsatz Ex 41 Sonder- schaltwerk 2 Ö...
  • Page 17: 1.22 Potentiometer

    Explosionsgeschützte Verteilungen GHG 619 Kontaktbelegung 1.22 Potentiometer Bemessungsspannung: bis max. 250 V Leistung: Drehbereich: 270° Skalierung: 0 - 100% Anschlussklemme: 2 x 1,0 - 2,5 mm² Prüfdrehmoment Anschlussklemmen: 2,5 Nm Gewicht: ca. 0,15 kg 1.23 Messinstrument AM/VM45 /AM/VM72 ATEX EG-Baumusterprüfbescheinigung: BVS 14 ATEX E 125U Gerätekennzeichnung nach 94/9/EG und Norm: Dreheisen...
  • Page 18: Steuerschalter Ex 23

    Explosionsgeschützte Verteilungen GHG 619 1.25 Steuerschalter Ex 23 Anschlussbilder Schaltung Schalter Ex 23 / Ex28 / Ex 29 EG-Baumusterprüfbescheinigung: BVS 13 ATEX E 107U Bemessungsspannung: bis max. 500 V Max. Bemessungsstrom: 10 A 6011 Schaltvermögen AC 15: 230 V / 6 A 400 V / 4,0 A Schaltvermögen DC 13: 24 V / 2 A...
  • Page 19: Flanschsteckdose 16 A

    Explosionsgeschützte Verteilungen GHG 619 Maßangaben in mm 1.28 Flanschsteckdose 16 A X=Befestigungsmaße EG-Baumusterprüfbescheinigung: PTB 99 ATEX 1040 U Gerätekennzeichnung nach 2014/34/EU und Norm: EN 60079-0 D II 2 G Ex de II C Flanschsteckdose 2-pol. + PE D II 2 D Ex tD A21 IP 66 T 80 °C IECEx Konformitätsbescheinigung IECEx BKI 04.0002 Gerätekennzeichnung: IEC60079-0...
  • Page 20 Explosionsgeschützte Verteilungen GHG 619 Kodierung / Code GHG 511 und GHG 512 GHG 511, 2-pol.+PE 110-130V 110-130V GHG 511 / GHG 512, 4-polig 50/60Hz 220-250V 380-415V 500V 500V blau schwarz schwarz GHG 511 / GHG 512, 5-polig 50/60Hz 220-250V 380-415V 500V 500V blau...
  • Page 21: Sicherheitshinweise

    Vor Öffnen der Gehäuse Spannungsfreiheit nen über die Chemikalienbeständigkeit der sicherstellen bzw. geeignete Schutzmaßnah- eingesetzten Kunststoffe bei Ihrer zuständigen men ergreifen. Cooper Crouse-Hinds Niederlassung erfragen. Die Mindestanschlussquerschnitte der druckfesten Komponenten sind beim Anschluss gemäß EN 60204-1:2005 zu beachten. Bei Verwendung eines Sammelschienensys- tems ist sicherzustellen, dass der Stoßkurz-...
  • Page 22: Verwendung / Eigenschaften

    Explosionsgeschützte Verteilungen GHG 619 5 mm). Steuerschaltervorsätze Ex 23 sind am Die Steckdosen für Niederspannungen sind mit Bild 4 Schalt kragen an der entsprechenden einem Lastschalter ausgestattet und sind bis Abschliessposition mit einer Bohrung Ø 5,5 mm max.16 A / 32 A einsetzbar (siehe technische zu versehen und somit über oben genanntes Daten), sie sind generell für den in der Vorhängeschloss abschließbar.
  • Page 23: Öffnen Des Gerätes / Elektrischer Anschluss

    Explosionsgeschützte Verteilungen GHG 619 Achtung: Die Anschlüsse für Zu- und Abgang Die Isolation muss bis an die Klemme Bild 7 des Sammelschienensystems sind so heranreichen. Der Leiter selbst darf nicht anzubringen, dass die Kupferschienen eine beschädigt sein. Gerätehalter für Rohrbefestigung Größe 3 gleichmäßige Strombelastung erhalten.
  • Page 24: Montage Doppelkabelendverschluss

    Explosionsgeschützte Verteilungen GHG 619 Bei Mischbestückungen Ex - e / Ex - i sind die Die für die eingebauten KLE maßgebenden Bild 8 erforderlichen Mindestabstände einzuhalten Montagerichtlinien sind zu beachten. (siehe z.B. EN/IEC 60079-11). Montageteile Doppelkabelendverschluss Montage Doppelkabelendverschluss siehe Die Errichtungshinweise für eigensichere Bild 8 und Bild 9: elektrische Betriebsmittel sind zu beachten.
  • Page 25: Flansche Und Metallplatten

    Signalleuchte, Taster usw.) in einschrauben. Übereinstimmung mit dieser Betriebsanleitung Instandsetzungsarbeiten / Reparaturen und anderen anwendbaren Bestimmungen zu dürfen nur mit Cooper Crouse-Hinds / CEAG Achtung: Beim Anziehen der Hutmutter der überprüfen. Originalersatzteilen vorgenommen werden. Metall-KLE ist die Verschraubung mit einem geeigneten Werkzeug gegen Verdrehen zu Bei Temperaturen unter -20 °C ist darauf zu...
  • Page 26: Technical Data

    *KLE = Cooper Crouse-Hinds plastic cable glands 2) Standard ambient temperature range of built-in industrial equipment is -25 ° C to + 55 ° C. Other temperatures on request with the manufacturer (Eaton's Crouse-Hinds Business).
  • Page 27: Bus-Bar System Up To Max. 180 A

    Explosion-protected distributions GHG 619 Bus-bar system up to max. 180 A Fig. 1 Connection diagrams EC-Type Examination Certificate: PTB 99 ATEX 1044 Explosion protection: Ex e II Rated voltage: up to 730 V AC Connection Rated current: max. 180 A up to 35 mm²...
  • Page 28: Circuit Breaker, 1-, 2-, 3-, 4-Pole Ghg 61

    Explosion-protected distributions GHG 619 Fig. 1.3.a Connection Main-; 1.3a Circuit breaker, 1-, 2-, 3-, 4-pole GHG 61 Aux.-/Signal contact EC-Type Examination Certificate: PTB 98 ATEX 1087U Explosion protection: Ex de II C Temperature range: for use in temperature classes T4-T6 Main contact Aux.
  • Page 29: 1�5 Elcb (Rccb), 2 And 4-Pole

    Explosion-protected distributions GHG 619 ELCB (RCD), 2- and 4-pole GHG61 Fig. 1.4. Connection Main contact EC-Type Examination Certificate: PTB 98 ATEX 1087U Explosion protection: Ex de II C Temperature range: for use in temperature classes T4-T6 Main contact Aux. contact Rated voltage: up to 440 V AC up to 250 V AC...
  • Page 30: Ghg624

    Explosion-protected distributions GHG 619 ELCB (RCCB), 2 and 4-pole; GHG624 Fig. 1.5 RCCB test buttom "TEST" Rated voltage: Main contact 230/400 V AC up to 240/415 V AC Pos. 1 Aux. contact up to 230V AC Rated current: Main contakt up to 63A Aux.contakt max.
  • Page 31: 1�5�B�5 Overload Release Ghg 62

    Explosion-protected distributions GHG 619 Contact arrangement 1.5.b.1 Signal contact GHG 62 additional devices Rated voltage: up to 230 V Rated current: Min. switching capacity: 5 mA at 24 V Signal contact Making/breaking capacity I (EN62019): AC 14 1 A / 400 V 2 A / 230 V DC 12 1 A / 220 V...
  • Page 32: Current Surge Switch

    Explosion-protected distributions GHG 619 Current surge switch Contact arrangement EC-Type Examination Certificate: PTB 98 ATEX 1087U Explosion protection: Ex de II C Temperature range: for use in temperature classes T4-T6 Rated voltage: up to 400 V AC 8 V to 275 V* AC 8 V to 220 V DC Rated operating voltage: * further operating voltages on request)
  • Page 33: 1�9 40 A Installation Contactor

    Explosion-protected distributions GHG 619 40 A installation contactor Contact arrangement EC-Type Examination Certificate: PTB 98 ATEX 1087U Explosion protection: Ex de II C Main contact Aux. contact Temperature range: for use in temperature classes T4 - T6 Rated voltage: up to 400 V AC 24 V to 275 V* AC Control voltage: (*further control voltages on request)
  • Page 34: Overvoltage Arrester

    Explosion-protected distributions GHG 619 1.12 Overvoltage arrester Contact arrangement EC-Type Examination Certificate: PTB 98 ATEX 1087U Explosion protection: Ex de II C Temperature range: for use in temperature classes T4 - T6 Rated operating voltage: max. 275 V AC Rated discharge surge current I max.
  • Page 35: Thermal Overcurrent Relay

    Explosion-protected distributions GHG 619 1.15 Thermal overcurrent relay Contact arrangement EC type examination Certificate: PTB 98 ATEX 1087U Explosion protection: Ex de II C Temperature range: for use in temperature classes T4 - T6 Rated voltage: up to 690 V AC up to 275 V* AC Control voltage: (*Further control voltages on request)
  • Page 36: Manual Motor Starter Up To 25 A

    Explosion-protected distributions GHG 619 1.18 Manual motor starter up to 25 A Dimension drawings EC type examination Certificate: PTB 99 ATEX 1007U Dimensions in mm Explosion protection: Ex de II C Temperature range: for use in temperature classes T5 -T6 Manual motor starter Rated voltage: 690 V, 50/60 Hz / 440 V DC...
  • Page 37: Operating Flap

    Explosion-protected distributions GHG 619 1.19 Operating flap Dimension drawings EC type examination certificate: PTB 99 ATEX 3107U Dimensions in mm Explosion protection: Ex e II Operating flap Weight- Size 1 flap: approx. 0,48 kg Weight- Size 2 flap: approx. 0,78 kg Size 1 MCB flap Size 2 MCB flap Click Frame 2...
  • Page 38 Explosion-protected distributions GHG 619 Dimensions drawings actuator Contact arrangements and indicator elements Dimensions in mm 2 NC 2 NO 1 NO + 1NC Puschbutton Double pushbutton actuator actuator 2 NC 2 NO 1 NO + 1NC Key-operated switch actuator Key-operated pushbutton actuator Circuity Code .061 6060...
  • Page 39: Potentiometer

    Explosion-protected distributions GHG 619 1.22 Potentiometer Dimensions drawings actuator and indicator elements EC type examination Certificate: IBExU14ATEX1030U Rated voltage: up to 250 V Dimensions in mm Rating: Turning range: 270° Scale: 0 - 100% Supply terminal: 2x 2,5 mm² 2,5 N Weight: approx.
  • Page 40: Ex 28 Control Switch

    Explosion-protected distributions GHG 619 1.26 Ex 28 control switch Contakt arrangements Circuitry Ex 23 / Ex28 / Ex 29 switch Code EC type examination certificate: BVS 14 ATEX E 076 U Rated voltage up to max. 500 V Rated current: max.
  • Page 41: 1.28 Flange Socket 16 A

    Explosion-protected distributions GHG 619 Dimensions in mm 1.28 Flange socket 16 A X = fixing dimensions EC type examination certificate: PTB 99 ATEX 1040 U Marking acc. to 2014/34/EU and standard EN 60079-0 D II 2 G Ex de II C Flange socket D II 2 D Ex tD A21 IP 66 T 80 °C 2-pol.
  • Page 42 Explosion-protected distributions GHG 619 Code GHG 511 and GHG 512 GHG 511, 2-pol.+PE 110-130V 110-130V GHG 511 / GHG 512, 4-pole 50/60Hz 220-250V 380-415V 500V 500V blue black black GHG 511 / GHG 512, 5-pole 50/60Hz 220-250V 380-415V 500V 500V blue black black...
  • Page 43: Safety Instructions

    The interlocking switch of the socket is mechanically secured and cannot be connected without plug. The sockets may only be used with the associated COOPER CROUSE-HINDS plugs in undamaged condition. The national safety rules and regulations for the prevention of accidents, as well as the...
  • Page 44: Application / Properties

    Explosion-protected distributions GHG 619 When required, the Ex 28 and Ex 29 control The apparatus connected to the plug shall Fig. 4 switches are provided with a locking facility that be suitable for the applied mains voltage. also allows them to be locked with a padlock. In order to switch on the socket, the plug is Details of the electric contacts are given on the inserted, pushed fully home and then turned...
  • Page 45: Opening Apparatus/Electrical Connection

    Explosion-protected distributions GHG 619 Only with the clickframe the degree of The insulation shall reach up to the terminal. Fig. 7 protection is IP66. The conductor itself must not be damaged. Warning: The connections for the incoming The minimum and maximum connectable Apparatus holder for pipe mounting, size 3 and outgoing leads of the bus bar systems conductor cross sections are to be observed.
  • Page 46: Cable Entries (Kle);Blanking Plugs

    Explosion-protected distributions GHG 619 Observe the datas and notes regarding the bus See Figs. 8 and 9 for how to Fig. 8 bar system GHG758 in the operating instruction assemble double cable end boxes: GHG 750 7002 P0001, enclosed separately.If Assembly pieces of the Undo the 2 fixing screws, Item 4, and the 3 connection terminals up to 240 mm²...
  • Page 47: Flanges And Metal Plates

    Putting into operation Fig. 10 Before putting the apparatus into operation, Only original Cooper Crouse-Hinds / CEAG Connection of bolt terminals up to 240 mm² the tests specified in the individual national parts shall be used for carrying out repairs.
  • Page 48: Tableaux De Distribution Ghg 619, Pour Atmosphères Explosives

    Tableaux de distribution GHG 619, pour atmosphères explosives Caracteristiques techniques Tableaux de distribution complet ATEX Certificat de Conformité: PTB 99 ATEX 1044 Marquage selon 94/9/CE et directive: EN 60079-0 D II 2 G Ex d e ia/ib m [ia/ib] IIC (IIB)T6/T5/T4 D II 2 D Ex tD A21 IP66/IP65 T80°C, T95°C Série limitée IECEx Certificat de Conformité:...
  • Page 49: Systèmes De Jeu De Barres À 180 A

    Tableaux de distribution GHG 619, pour atmosphères explosives Systèmes de jeu de barres à 180 A Fig. 1 Schémas de connexion Attestation d’examen type CE: PTB 99 ATEX 1044 Mode de protection: Ex e II Tension d’essai: jusqu’à 730 V AC Connexion Courant d’essai: 180 A maxi.
  • Page 50: Disjoncteurs À 1, 2, 3, 4 Pôles Ghg 61

    Tableaux de distribution GHG 619, pour atmosphères explosives Fig. 1.3.a Connection Main-; 1.3a Disjoncteurs à 1, 2, 3, 4 pôles GHG 61 Aux.-/Signal contact Attestation d’examen type CE: PTB 98 ATEX 1087U Mode de protection: Ex de II C Température d’utilisation: Classes de température T4 - T6 Contacts principaux - jusqu’à...
  • Page 51: 1�4 A

    Tableaux de distribution GHG 619, pour atmosphères explosives Interrupteurs différentiels bi- et tétrapolaire GHG61 Fig 1.4 Schéma de connexion Attestation d’examen type CE: PTB 98 ATEX 1087U Mode de protection: Ex de II C Température d’utilisation: Classes de température T4 - T6 Contacts principaux - jusqu’à...
  • Page 52: Interrupteurs Différentiels Bi- Et Tétrapolaire

    Tableaux de distribution GHG 619, pour atmosphères explosives Interrupteurs différentiels bi- et tétrapolaire; GHG624 Fig 1.5 Schéma de raccordement Tension d’essai: Contacts principaux - 230/400 V ACà 240/415 V AC FI bouton de circuit Contacts auxiliaires - jusqu’à 230V AC "TEST"...
  • Page 53: 1�5�B�1 Contacts De Signalisation Ghg62

    Tableaux de distribution GHG 619, pour atmosphères explosives Schéma de raccordement 1.5.b.1 Contacts de signalisation GHG62 accessories Tension d’essai: jusqu’à 230 V Courant d’essai: Min. Courant d’essai: 5 mA à 24 V Contacts de signalisation Pouvoir de fermeture I (EN62019): pouvoir de coupure AC 14 1 A / 400 V...
  • Page 54: Interrupteur De Coupure À Impulsion

    Tableaux de distribution GHG 619, pour atmosphères explosives Interrupteur de coupure à impulsion Schéma de connexion Attestation d’examen type CE: PTB 98 ATEX 1087U Mode de protection: Ex de II C Température d’utilisation: Classes de température T4 - T6 Tension d’essai: jusqu’à...
  • Page 55: Contacteur D'installation 40 A

    Tableaux de distribution GHG 619, pour atmosphères explosives Contacteur d’installation 40 A Schéma de connexion Attestation d’examen type CE: PTB 98 ATEX 1087U Mode de protection: Ex de II C Température d’utilisation: Classes de température T4 - T6 Contacts principaux Contacts auxiliaires Tension d’essai: jusqu’à...
  • Page 56: Protection De Surtension

    Tableaux de distribution GHG 619, pour atmosphères explosives 1.12 Protection de surtension Schéma de connexion Attestation d’examen type CE: PTB 98 ATEX 1087U Mode de protection: Ex de II C Température d’utilisation: Classes de température T4 - T6 Tension d’utilisation réseau: 275 V AC maxi.
  • Page 57: Dimensions

    Tableaux de distribution GHG 619, pour atmosphères explosives 1.15 Relais thermique Schéma de connexion Attestation d’examen type CE: PTB 98 ATEX 1087U Mode de protection: Ex de II C Température d’utilisation: Classes de température T4 - T6 Tension d’essai: jusqu’à 690 V AC jusqu’à...
  • Page 58: Démarreur Moteur Manuel - Jusqu'à 25 A

    Tableaux de distribution GHG 619, pour atmosphères explosives 1.18 Démarreur moteur manuel - jusqu’à 25 A Dimensions Attestation d’examen type CE: PTB 99 ATEX 1007U Valeurs en mm Mode de protection: Ex de II C Température d’utilisation: Classes de température T5 -T6 Démarreur moteur manuel Tension d’essai: 690 V, 50/60 Hz / 440 V DC...
  • Page 59: Fenêtre Pour Operation

    Tableaux de distribution GHG 619, pour atmosphères explosives 1.19 Fenêtre pour operation Dimensions Attestation d’examen CE de type: PTB 99 ATEX 3107U Valeurs en mm Mode de protection: Ex e II Fenêtre pour operation Poids- fermée ouverte fenêtre taille 1: env.
  • Page 60 Tableaux de distribution GHG 619, pour atmosphères explosives Schémas de connexion Dimensions des éléments de comman de et d’affichage Valeurs en mm 2 NF 2 NO 1 NO + 1NF Face avant de - bouton-poussoi double bouton-poussier 2 NF 2 NO 1 NO + 1 NF Face avant d’interrupteur à...
  • Page 61: Potentiomètre

    Tableaux de distribution GHG 619, pour atmosphères explosives 1.22 Potentiomètre Dimensions des éléments de comman de et d’affichage Attestation d’examen CE de type: IBExU14ATEX1030U Tension d’essai: jusqu’à 250 V Valeurs en mm Puissance: Domaine de rotation: 270° Echelle: 0 - 100% Diamètre de connexion: 2x 2,5 mm²...
  • Page 62: Commutateur De Comande Ex 28

    Tableaux de distribution GHG 619, pour atmosphères explosives 1.26 Commutateur de comande Ex 28 Schémas de connexion Code Commutateurs Ex 23 / Ex 28 / Ex 29 Attestation d’examen type CE: BVS 14 ATEX E 076 U Tension d’essai: jusqu’à 500 V maxi. Courant d’essai maxi.: 20 A 6011...
  • Page 63: Prise À Bride 16 A

    Tableaux de distribution GHG 619, pour atmosphères explosives Dimensions en mm 1.28 Prise à bride 16 A X=dimensions de fixation ATEX Certificat de Conformité: PTB N° 99 ATEX 1040 U Marquage selon 2014/34/UE et directive EN 60079-0 D II 2 G Ex de II C Prise à...
  • Page 64 Tableaux de distribution GHG 619, pour atmosphères explosives Code GHG 511etGHG 512 GHG 511, 2-pôl.+PE 110-130V 110-130V GHG 511 / GHG 512, 4-pôl. 50/60Hz 220-250V 380-415V 500V 500V bleu rouge noir noir GHG 511 / GHG 512, 5-pôl. 50/60Hz 220-250V 380-415V 500V 500V...
  • Page 65: Consignes De Sécurité

    Lors des raccordements, les diamètres de succursale Cooper Crouse-Hinds de votre connexion des composants encapsulés région. doivent être respectés selon CEI/EN 60204-1:2005.
  • Page 66: Utilisation / Propriétés

    Tableaux de distribution GHG 619, pour atmosphères explosives Les commutateurs Ex 28 et Ex 29 sont Pour la mise en circuit de la prise, la fiche doit Fig. 4 disponibles avec un système de verrouillage en être enfichée jusqu’à sa butée dans celle-ci et option et cadenassables de la même manière.
  • Page 67: Ouverture De L'enveloppe / Raccordement Électrique

    Tableaux de distribution GHG 619, pour atmosphères explosives Les tableaux en polyester se fixent sur les Les jeux de barres et bornes à visser montés Fig. 7 supports taille 3 avec des vis taraudées ou doivent être raccordés avec des cosses DIN autotaraudeuses (voir Fig.
  • Page 68: Entrées De Câble Et Bouchons Obstruateurs

    Tableaux de distribution GHG 619, pour atmosphères explosives Le schéma de connexion des composants Retirer les 2 vis de fixation (Pos. 4) et les Fig. 8 figure sur le socle de ceux-ci et joint à l’appareil. 3 autres vis de fixation (Pos. 12) de la partie Eléments de montage des boîtiers Il est également représenté...
  • Page 69: Plaques De Fond Et Plaques Métalliques

    Voir la note sur le Seules des pièces de rechange d’origine système. Dans les systèmes avec la Cooper Crouse-Hinds / CEAG ne doivent être préparation de clôture de chauffage interne utilisées pour les travaux de réparation / est signalé par un thermostat.
  • Page 70: Test Torques For Terminal Rows

    Anzugsprüfdrehmomente Test torques Couple de serrage testés für Reihenklemmen for terminal rows de connexion des bornes Anzugsprüfdrehmomente (Nm) Test torques (Nm) Couple de serrage testés (Nm) Hersteller/Typ Klemmbereich (mm²) Manufacturer/Type Terminal cross section (mm²) Fabricant/Typé Diamètre de connexion (mm²) Phönix Phönix Weidmüller WDU/WPE...
  • Page 71: 11.2 Capri Ade 4F

    11.2 Capri ADE 4F 11.2 Capri ADE 4F 11.2 Capri ADE 4F Leitungs- Leitungs- durchmesser Gewinde Größe durchmesser Größe Bestellnummer ADE 4F (äußerer (innerer Mantel) Mantel) Cable sealing Cable sealing Gland Type Thread size range range Order No. ADE 4F size (inner sheath) (outer sheath)
  • Page 72: 11.3 Les Entrées De Câbles En Plastique

    11.3 Kunststoff Kabel-/Leitungseinführung 11.3 Plastic cable entries 11.3 Les entrées de câbles en plastique Gewicht ca. Type Weight approx. Type Poids env. M12x1,5 15 mm 19,3 mm 8 mm 16,2 mm M16x1,5 20 mm 23,0 mm 8 mm 22,0 mm M20x1,5 24 mm 25,0 mm...
  • Page 73: Dimensional Drawings

    Maßbilder Dimensional drawings Plans cotés Maßbilder Edelstahlgehäuse Maßbilder Kunststoffgehäuse Dimension drawings for moulded plastic Dimension drawings for stainless steel enclosures enclosures Dimensions des enveloppes en matière Dimensions des enveloppes acier inoxydable plastique Gehäusegröße 1 Size 1 Taille 1 Gehäusegröße 2 Size 2 Taille 2 Gehäusegröße 3...
  • Page 74 Maßbilder GHG 61 Dimensional drawings GHG 61 Plans cotés GHG 61 X = Befestigungsmaße X = Fixing dimensions X = Dimensions de fixation Komponentengröße 0 Komponentengröße 1 Komponentengröße 2 Module size 0 Module size 1 Module size 2 Tailles d’modulés 0 Tailles d’modulés 1 Tailles d’modulés 2 Komponentengröße 3...
  • Page 75: Multiples Du Courant Mesuré S 280 Uc

    Auslösekennlinien Tripping characteristic of Courbe de déclenchement circuit breaker du disjoncteur C - Charakteristik K - Charakteristik B - Charakteristik S200; S200 M; S200 P; S200; S200 M; S200 P; S200; S200 M; S200 P; S260; S270; S280 S270; S280 S260;...
  • Page 76 H: "A kezelési útmutatót az adott ország P: "Se for necessária a tradução destas ve svém mate ském jazyce u p íslušného nyelvén a Cooper Crouse-Hinds/CEAG cég instruções de operação para outro idioma da zastoupení spole nosti Cooper Crouse- helyi képviseletén igényelheti meg."...