• The probe may need recalibration, please follow the instructions in your manual to recalibrate the
probe. You should recalibrate each of your probes every 3 months to maintain accuracy. If the problem
isn't resolved you may need to replace the probe.
No power to Lifeguard
• Check that the IEC plug in the back of the Lifeguard is inserted properly and secured through the cable
retention feature.
• Check that the power to your power outlet is switched on
• Your unit may need repair, please call your nearest Davey pool dealer
EcoSalt2 is not connected to Lifeguard
• If your EcoSalt2 chlorinator is not displaying Lifeguard on the screen check that the RJ45 cable is
connected from the back of your EcoSalt2 to your Lifeguard.
• Check the "N" symbol on your Lifeguard is solid (refer Section 7).
• Lifeguard will need to be powered before the EcoSalt2 on first time start up.
• DPLGEU only - Lifeguard should be always powered, the Ecosalt2 should be run on a timer/schedule.
• It may be necessary to force a software update – make sure your Lifeguard is connected to wifi then
hold the down button on your Lifeguard down until the screen goes blank, it will update your Lifeguard
to the latest version. Once complete, hold the back button down until the screen goes blank, this will
update your EcoSalt2.
• Your unit may need repair, please call your nearest Davey pool dealer
Lifeguard is showing low flow alarm
• If your pump is running check that the set speed is high enough for your pool installation, you may
need to increase the speed.
• Ensure any valves including the filter multiport valve is set to the correct position.
• Check that your flow sensor isn't jammed off and is free from any debris and is in the correct
flow direction.
• You may need to Backwash your sand filter to reduce the flow restriction.
Lifeguard is showing low salt alarm
• Check that your salt levels are in range.
Lifeguard screen is black
• If your unit is in direct sunlight this can occur.
• Screen should return to normal when cool.
• Install shade or move unit out of direct sunlight.
Lifeguard screen is blank
• Ensure there is power to the unit.
• Try resetting the Lifeguard by disconnecting and reconnecting the power to the unit.
• Your unit may need repair, please call your nearest Davey pool dealer
Clicking sound coming from EcoSalt2
• This usually indicates that the flow is a bit too low for your installation and the flow switch is not staying
on consistently. Increase the speed on your pump to correct the problem.
• You may need to Backwash your sand filter to reduce the flow restriction.
I cannot connect to wifi
• Check that your home wi-fi is working and you have a full strength wi-fi signal at your pool equipment
installation (refer Section 7).
• You may need to install a wi-fi extender to boost the signal to that area.
• Check that your antenna is properly installed on your Lifeguard unit.
68
▲ CONTENTS