Cover Mode; Activating Cover Mode On Davey Lifeguard Control Panel - Davey DPLGEU Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71

9.6 COVER MODE

The Davey Lifeguard is compatible with large swimming pool applications as well as much smaller spa
applications. COVER MODE is only applicable when NO ORP probe is connected. Turning on the COVER
MODE reduces the chlorinator cell duty cycle by 80% of its current setting.
For example:
• If the EcoSalt2 is on for 10 hours per day, the CHLORINE OUTPUT is set to 50%, and COVER MODE
is off: the EcoSalt2 cell duty cycle is 5 hours of that day.
• However, if the EcoSalt2 is on for 10 hours per day, the CHLORINE OUTPUT is set to 50%, and
COVER MODE is on: the EcoSalt2 cell duty cycle is only 1 hour of that day.
• Similarly, if the EcoSalt2 is on for 10 hours per day, the CHLORINE OUTPUT is set to 25%, and
COVER MODE is on: the EcoSalt2 cell duty cycle is only 30 minutes of that day.
Reminder: COVER MODE can only be selected from the menu if ORP probe is not connected.

9.6.1. Activating Cover Mode on Davey Lifeguard control panel

• From the HOME SCREEN, press the
buttons to scroll down to MODES (ref Figure 9.33), then select by pressing the
menu/setting select button.
Figure 9.33
• Press the
menu up/down buttons to scroll down to COVER (ref Figure 9.34), then select by
pressing the
menu/setting select button.
Figure 9.34
menu/setting select button. Press the
main:
-> modes
settings
maintenance
mODES:
backwash
spa
-> cover
58
Off
OFF
OFF
▲ CONTENTS
menu up/down

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières