12. TROUBLESHOOTING

12.1 WARNINGS AND ALARMS

Message
Warning or Alarm
on Davey
Lifeguard
Low Salt Warning SALT LOW
Low Salt Alarm
SALT LOW
Check Pool Chem
CHECK POOL
Alarm
CHEM
Flashing icons
WiFi Disconnected
Warning
pH Low Warning
PH LOW
pH Low Alarm
PH LOW
pH High Warning
PH High
pH High Alarm
PH HIGH
ORP Low Warning ORP LOW
ORP High Warning ORP HIGH
ORP High Alarm
ORP HIGH
ORP Low Alarm
ORP LOW
Low Flow Alarm
FLOW LOW
SETUP
Setup Incomplete
INCOMPLETE
Cause for Alarm
Low Salt Models - salt reading
of 1500ppm or below.
Regular Models - salt reading
of 3000ppm or below.
Low Salt Models - salt reading
of 1200ppm or below.
Regular Models - salt reading
of 2500ppm or below.
Dirty cell or inaccurate pool
chemistry.
Davey Lifeguard is
disconnected from WiFi.
If a pH reading is great than or
equal to 0.2pH units less than
set point is recorded.
If a pH reading of 6.8 or below
is recorded.
If a pH reading greater than
or equal to 0.2pH points more
than set point is recorded.
If a pH reading of 8 or above
is recorded.
If an ORP reading greater
than or equal to 100mV points
less than set point is recorded.
If ORP reading is greater than
or equal to 100mV more than
set point.
If the ORP reading of 1,000mV
or higher is recorded.
If an ORP reading is 335mV
or below.
A flow rate below 60L/min
(3.6m
/h)
3
The first time set-up process
was not completed.
65
How alarm is cleared
Once the Davey Lifeguard registers
a salt concentration within range the
warning will clear.
Once the Davey Lifeguard registers a
salt concentration within range the alarm
will clear and the Davey Lifeguard will
return to normal operation once the
System on/off button is pressed.
Cell will have turned off. Check cell
is clean and clean if required. Have a
full analysis of water done and make
sure that all parameters are within
the recommended range in the table
(Figure 10.1 next page). Press the
SELECT button to clear the alarm.
Davey Lifeguard will attempt to re-
connect itself to WiFi. If this does not
happen automatically press and hold
the SELECT button for 5 seconds
and until both icons will toggle to
re-establish internet connection.
Connection is established when both
icons are stable.
Will clear automatically once pH is
within 0.2pH units away from set point.
Will clear automatically once pH is
raised above 6.8.
Will clear automatically once pH is
within 0.2pH units away from set point.
Will clear automatically once pH is
below 8.
Will clear automatically once ORP is
within 100mV of set point.
Will clear automatically once ORP is
within 100mV of set point.
Will clear automatically if once ORP
reading is lower than 1,000mV.
Will clear automatically once ORP is
above 335mV.
Fault is cleared instantly and automatically
once correct flow is detected.
Select FACTORY RESET and
complete the process.