Figure 6.24
It should be noted that Chlorine's effectivity is related to the pool water's ORP level as explained in
Section 3. Davey recommends following the pool levels shown in Section 10. Adjustment to the ORP
set point can be made as follows:
• Use the
menu up/down buttons to scroll to your desired set point. Once correct, then
press
menu/setting select.
Should you select NO for "Is the ORP probe connected?" you will be shown a screen to choose a Chlorine
Output. This step is only necessary if you select NO ORP probe. Should you wish to control the Chlorine
output manually, Lifeguard's Chlorine output works the same as explained in the EcoSalt2 manual. Refer to
the relevant section following URL: www.bit.ly/EcoSalt2
6.7 SALT PROBE MENU
• The next screen shown asks if the salt/conductivity probe is currently connected and to be used
(refer Figure 6.25);
Figure 6.25
• If you've chosen not to use the salt probe, skip to section 7 of this manual;
• Use the
menu up/down buttons to toggle between yes and no. Once correct, then
press
menu/setting select.
• If you've chosen to use the salt probe, the next screen will display 0ppm salt (refer Figure 6.26).
Figure 6.26
ORP set point:
-> 650 MV
is the salt probe
connected?
->yes
salt
calibration:
actual reading
->
0 ppm
26