• Press the
Figure 8.43
• Press the
Figure 8.44
• Press the
menu/setting select button;
Figure 8.45
• Now follow the instructions for ORP calibration from Section 6.6.
8.2.2.2. Using the app
Note: the ORP probe cannot be calibrated via the app.
8.2.3. Overriding/ignoring ORP probe
Should the need arise whereby the ORP probe needs to be isolated (turned off, or ignored) this is
possible both via the Davey Lifeguard control panel, or via the Davey Lifeguard app. This may become
necessary if the probe is damaged during a maintenance clean. If the probe is damaged, refer to
maintenance Section 11.
8.2.3.1. On the Davey Lifeguard control panel
• From the HOME SCREEN, press the
main menu (Figure 8.46);
menu up/down button to scroll down to maintenance (Figure 8.43);
main:
SETTINGS
-> maintenance
ABOUT
menu up/down button (Figure 8.44);
maintenance:
-> calibration
clean cell
replace cell
menu up/down buttons to scroll down to ORP CAL (Figure 8.45). Then press the
calibration:
ph cal
-> orp cal
salt cal
menu/setting select button. This will now show the
43
▲ CONTENTS