loG PlacemenT

FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE
ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY
LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE
PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED
THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE.
phazer
logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is
Tm
different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect.
Log colours may vary. During the initial use of the fireplace, the colours will become more uniform as colour
pigments burn in during the heat activated curing process.
a.
Place the rear log (w135-0136) onto the two log
supports and against the air intake pipe.
C.
Fit the centre log (w135-0139) into place behind
the left log and into the pocket provided on the
rear log.
4.4

GlowinG embers

Tear the embers into pieces and place along the front
row of ports covering all of the burner area in front of the
logs. Care should be taken to shred the embers into thin,
small irregular pieces as only the exposed edges of the
fibre hairs will glow. The ember material will only glow
when exposed to direct flame; however, care should
be taken to not block the burner ports.
blocked burner ports can cause an incorrect flame
pattern, carbon deposits and delayed ignition.
phazer
logs glow when exposed to direct flame. use only certified "glowing embers" and phazer
Tm
available from your authorized dealer / distributor.
WARNING
!
DAMAGE OR PERSONAL INJURY.
IGNITION MAY OCCUR.
a
c
b
b.
Position the left log (w135-0137) and the right log
(w135-0138) against the grate posts and line up
the studs located on the burner with the holes on
the bottom of the logs. Keep slightly back of the
front row of ports.