oPTional wall swiTcH

EN
Do Not CoNNeCt the wall swItCh or Gas valve DIreCtly to 110 volt eleCtrICIty.
For ease of accessibility, an optional remote wall switch may be installed in a convenient location. Route a
2 strand, solid core millivolt wire from the valve to the wall switch. The recommended maximum lead length
depends on wire size:
wiRe SiZe
14 gauge
16 gauge
18 gauge
Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch.

4.0 finisHinG

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING.
W415-1366 / 10.15.14
MAX. LeNgth
100 feet (30.5m)
60 feet (18.3m)
40 feet (12m)
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED.
REMOVED, CRACKED, BROKEN OR SCRATCHED.
WARNING
!
3
TP
1
WARNING
!

RISK OF FIRE!

50.5
72.1A