2.4
General informaTion
for your satIsfaCtIoN, thIs aPPlIaNCe has beeN test-fIreD to assure Its oPeratIoN aND
qualIty!
Altitude (FT)
Max. Input (bTu/HR)
Max. Output (bTu/HR)
Efficiency (w/the fan on)
A.F.u.E. (maximum value)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (under Flow Conditions)
when the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion
/ contraction noises during heating up and cooling down cycles are
normal and to be expected.
This appliance is not approved for closet or recessed installations. It
is approved for bathroom, bedroom and bed-sitting room installations
and is suitable for mobile homes. The natural gas model is suitable for
installation in a mobile home that is permanently positioned on its site
and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
GDIZC
NG
0-4,500
24,000
20,400
85%
79%
4.5" (11mb) water Column
7" (17mb) water Column
3.5" (9mb) water Column
lP
0-4,500
24,000
20,400
85%
79%
11" (27mb) water Column
13" (32mb) water Column
10" (25mb) water Column
65.5%
GDIZC
65.5%
CDIZC
W415-1366 / 10.15.14
7
EN