18
6.0 adjusTmenTs
6.1
PiloT burner adjusTmenT
EN
Remove the pilot screw cap. Adjust the pilot screw to provide properly
sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.
Re-install the pilot screw cap.
Inlet pressure can be checked by turning screw (A) counter-
clockwise until loosened and then placing pressure gauge tubing over
the test point. Gauge should read as described on the chart below.
Check that main burner is operating on "HI".
Outlet pressure can be checked the same as above using screw (b).
Gauge should read as described on the chart below. Check that main
burner is operating on "HI".
after taKING Pressure reaDINGs, tIGhteN sCrews
fIrmly to seal. Do Not over torque. leaK test.
Prior to pilot adjustment, ensure that the pilot assembly has not been
painted. If overspray or painting of the pilot assembly has occurred
remove the paint from the pilot assembly, or replace. Fine emery
cloth or sandpaper can be used to remove the paint from the pilot
hood, electrode and fl ame sensor.
6.2
venTuri adjusTmenT
This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
3" / 3" Liner System
NG
lP
This appliance is approved for use with a 2" (51mm) liner for air intake and a 3" (76mm) liner for exhaust. For best performance,
however, it is recommended to use two 3" (76mm) liners.
W415-1366 / 10.15.14
aIr shutter settING
2" / 3" Liner System
1/16" (2mm)
3/16" (5mm)
Natural Gas
Pressure
Inlet
Outlet
1/8" (3mm)
5/16" (8mm)
PILOT
BURNER
THERMOCOUPLE
b
A
PIlot sCrew
Natural Gas
Propane
(inches)
(millibars)
(inches)
7"
17.4mb
13"
(MIN. 4.5")
(MIN. 11.2mb)
(MIN. 11")
3.5"
8.7mb
10"
39.6b
VENTURI
BURNER
ORIFICE
49.1
THERMOPILE
Propane
(millibars)
32.4mb
(MIN. 27.4mb)
24.9mb
AIR
SHUTTER