the display shows:
MAINTENANCE ALARM AND RESET
When this indication appears on the
where xxx is the telephone number set as a suggestion, it means that the number of cycles that
can be performed (coffees distributed) as set in the TECHNICAL LEVEL Programming has been
exceeded
To reset this signal it is sufficient to supply power to the doser by holding down the buttons
K1GR1 and K2GR1 simultaneously.
the display shows:
RESET TOTAL SINGLE DOSES
It is possible to reset the count of the consumption of single doses.
To reset this signal you have to go to TECHNICAL LEVEL Programming, to the Total Reading menu, and hold down the buttons K3GR1 and
K4GR1 simultaneously for 3 seconds.
the display shows:
the display shows:
ATTENTION: the total derived from the sum of all the distributions made for each button of each group cannot be reset.
Note: the consumption reset operation DOES NOT RESET the reading of the litres consumed; to reset this, refer to the specific
paragraph.
The factory presetting allows you to delete the data memory completely and load standard values for all the memorised data.
This must be carried out, for example, after the programming of the
microprocessor (on board software OBP) if that has also reset its
EEPROM memory, or when a software update has affected one or more
stored data or added new ones.
So when switching on, hold down the buttons
K1GR1 + K3GR1 + K5GR1 simultaneously.
When preset is completed, the following appears on the display:
the display shows:
To return to normal operation you must switch off and on again.
After a factory preset it is necessary to recheck and if necessary reset all the machine parameters (bar/technician/factory/roaster),
including the respective passwords (except the factory password which is fixed).
The factory preset also resets all the counters, including the total doses made.
PROCEDURES IN THE EVENT OF A POWER CUT
In the event of an interruption in the power supply, when power returns the doser resumes the status (IDLE-ON or OFF) that it was in at the time of
the power cut.
Any distributions in progress are aborted.
All dosing data are memorised.
Filter Reset
Service
display:
xxxxxxxx
Service Reset
Coffees total
Coffees total
Total Reset
PRESET DEFAULT DATA
Preset valori
completato
Pressing buttons for 3 seconds
Hold down simultaneously when switching on
66
Pressing buttons to switch on the system
Only group 1 keyboard