ELECTRONIC CONTROL
ELEKTRICAL INSTALLATION
The electronic control unit supplied is required for operation
of the wing gate actuator. This control unit comprises an
electronic microprocessor-control system employing the
latest technology. It may be used for the connection of 1 or 2
motors and offers all connection possibilities and functions
necessary for safe and reliable operation.
The electrical connections for single- or double gates are
given in Illustration 9.
The control box containing the motor control module is to be
fitted with cable entry at bottom (Illustration 10). It should
not be continuously exposed to direct sunlight. For weather
protection, we recommend the fitting of a small protection
roof.
Thanks to the electronic control unit, fine adjustment of the
push-pull torque is possible. When correctly adjusted, gate
movement can be easily blocked by hand.
For the OPEN and CLOSED positions, the gate requires
a stable end stop as the swing gate actuator unit is not
fitted with limit switches and the electronic controls are
switched off by time.
CONNECTION OVERVIEW
The control unit should be connected up last, i.e. after the
motor has been mounted, the necessary cables laid and the
Infrared Sensors or contact strips fixed in place.
In the case of permanent mounting, means of separating the
system from the mains must be provided. The contact
spacing of the main switch used in this connection must be
at least 3 mm.
NOTE:
In these instructions, relay contacts are designated as
NC (normally closed) and NO (normally open).
• NC contacts are closed, and open when actuated.
• NO contacts are open, and close when actuated.
8
2
8
OVERVIEW
TERMINAL
DESCRIPTION
PE
Earth supply cord
PE
Earth motor 1
PE
Earth motor 2
Capacitor motor1
C1
Direction CLOSED (L1.1) motor 1
1
2
MP
3
Direction OPEN (L1.2) motor 1
Capacitor motor 1
C1
C2
Capacitor motor 2
4
Direction CLOSED (L1.1) motor 2
5
MP
Direction OPEN (L1.2) motor 2
6
C2
Capacitor motor 2
7
Flashing light MP 230Volt ˜
8
Flashing light L1 230Volt ˜
E-lock drive NO
9
10
E-lock drive NO
11A
Safety input OV (socket module 1)
Safety input +24V (socket module 1)
12A
Switching input 1 (socket module 1)
13A
14A
Limit switch contact 1 (factory bridged)
15A
Limit switch contact 1 (factory bridged)
Push button motor 1 only, NO
16A
17A
Push button motor 1 only, NO
11B
Safety input 0V (socket module 2)
12B
Safety input +24V (socket module 2)
Switching input 2 (socket module 2)
13B
14B
Limit switch contact 2 (factory bridged)
15B
Limit switch contact 2 (factory bridged)
16B
Push button motor 1 + 2 NO
Push button motor 1 + 2 NO
17B
FUNCTION AND DESCRIPTION OF DIP SWITCHES
Dip switch 1
ON - IR Sensor
OFF - Contactstrip
only for socket module 2 in connection with
module 801696
Dip switch 2
ON - Reversal to direction "OPEN" after
recognizing the obstacle
OFF - Stop - after recognizing the obstacle
Dip switch 3
ON = Dead man's operation on
OFF = Dead man's operation off
FUNCTION AND DESCRIPTION OF POTENTIOMETERS
Potentiometer 1 Operating times up to 45 seconds
(safety function only, i.e. set to longer than
actually required)
Potentiometer 2 Delay operation of second door up to
120 seconds
Potentiometer 3 Automatic admission up to 120 seconds
DESCRIPTION OF LEDS
LED1 Impulse to M1+M2
LED2 Impulse to M1
(Pedestrian-Function)
on: Impulse
off: no Impulse
on: Impulse
off: no Impulse