Fault
Cause
Fastener system
Foreign objects in
jammed
zipper mechanism
Excess friction
Chemical
Fastener system
protective suit
not closed
leaky
Suit material
damaged
Safety boots or
gloves faulty or
leaky joint
Valve disc or seat
dirty or faulty
Full face mask or
face cuff leaking
Chemical
Valve disc on suit
protective suit not
valve sticks
ventilated
Hook-and-loop
Hook-and-loop
strap becomes
strap is attached
detached
with adhesive.
Cleaning and
decontamination
can cause it to
become loose.
1
not part of the EU prototype tests
30
1
Remedy
Clean zip fastener,
remove foreign
objects.
Lubricate zip
fastener with
grease stick.
Close fastener
system
completely.
Repair with suit
repair kit. Check
for leaks again.
Replace or seal.
Check for leaks
again.
Clean or replace.
Check for leaks
again.
Replace or seal.
Check for leaks
again.
Clean or replace.
Check for leaks
again.
Re-adhere hook-
and-loop strap.
Check for leaks
again.