1.4 Technical specifications
Pac Alpha
Single phase voltage
Power consumption*
Power restored*
Nominal current consumption*
COP*
Sound power
Sound pressure at 10 meters
Protection calibre
* with an ambient air of +15 °C and a pool water of 24 °C, humidity 70%
unit protection class: IP 24
refrigerant gas: R410A
refrigerant charge: see product information plate
2. Installation
Do not pick up the unit using the outer casing, use the base to lift and move the unit.
2.1 Selecting an installation site
The appliance must be installed outdoors and there must be adequate open space surrounding it (see
§2.4).
The heat pump must be installed at a minimum distance from the end of the pool so as to avoid exposure to
water splashes. The appropriate distance should be defined with reference to the national electrical standards
that apply in the country of installation (in France: 3.5 meters).
The heat pump must not be installed:
- near a heat source or near inflammable gas,
- near a road with a risk of water and mud splashes,
- facing strong wind,
- with the vent facing toward a permanent or temporary obstacle (window, wall, hedge, etc...), it must be at
least 3meters from such.
2.2 Installing the appliance
place onto a stable, solid (concrete slab type) and level surface,
protect from risks of flooding due to condensation produced by the appliance whilst it is operating (see §2.4).
It is possible to fix the appliance to the ground using the holes in the base of the appliance (fixings not
supplied).
A drilling explanation diagram is available on the rear of the packaging box.
2.3 Hydraulic connections
Respect the direction of the hydraulic connection (see § "Dimensions" in the appendix).
The connection uses a Ø40 pipe, with ½ union fittings, on the pool filtering circuit, after the filter and before
water treatment . It is possible to connect using Ø32/Ø38 or Ø50, using the supplied adapters,
Installing a bypass is mandatory and makes interventions on the appliance easier,
Adjust the water flow rate using valve VB, and keep valves VE and VS open,
check the tightening of the hydraulic connections, and for leaks.
H04019‐00.A3.EN – 2013/01
ML1_Pac Alpha Ed 01-2013-noir.indd 14
5M
kW
0.98
kW
4.65
A
4.45
4.7
dBA
65.4
dBA
37.4
A
7M
230V‐50Hz
1.56
6.52
7.09
4.2
66.7
38.7
16
Fixing holes
9M
11M
2.06
2.6
8.6
10.5
9.36
12.4
4.2
4.1
69
72
41
44
3