Technical Specifications; Installation; Selecting An Installation Site; Installing The Appliance - Zodiac Pac Alpha 5M Notice D'installation Et D'utilisation

Masquer les pouces Voir aussi pour Pac Alpha 5M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.4 Technical specifications  
 
Pac Alpha 
Single phase voltage 
Power consumption*    
Power restored* 
Nominal current consumption* 
COP* 
Sound power 
Sound pressure at 10 meters 
Protection calibre 
* with an ambient air of +15 °C and a pool water of 24 °C, humidity 70% 
 unit protection class: IP 24 
 refrigerant gas: R410A  
 refrigerant charge: see product information plate 
 
2. Installation 
 
Do not pick up the unit using the outer casing, use the base to lift and move the unit. 
 
 
2.1 Selecting an installation site 
 
The appliance must be installed outdoors and there must be adequate open space surrounding it (see 
 
§2.4). 
 
 The heat pump must be installed at a minimum distance from the end of the pool so as to avoid exposure to 
water splashes. The appropriate distance should be defined with reference to the national electrical standards 
that apply in the country of installation (in France: 3.5 meters). 
 The heat pump must not be installed:  
- near a heat source or near inflammable gas,  
- near a road with a risk of water and mud splashes,  
- facing strong wind,  
- with the vent facing toward a permanent or temporary obstacle (window, wall, hedge, etc...), it must be at 
least 3meters from such.  
 
2.2 Installing the appliance 
 
 place onto a stable, solid (concrete slab type) and level surface,   
  protect from risks of flooding due to condensation produced by the appliance whilst it is operating (see §2.4). 
 
 
 
It  is  possible  to  fix  the  appliance  to  the  ground  using  the  holes  in  the  base  of  the  appliance  (fixings  not 
supplied). 
 
A drilling explanation diagram is available on the rear of the packaging box. 
 
2.3 Hydraulic connections 
 
Respect the direction of the hydraulic connection (see § "Dimensions" in the appendix). 
 
 
 The connection uses a Ø40 pipe, with ½ union fittings, on the pool filtering circuit, after the filter  and before 
water treatment . It is possible to connect using Ø32/Ø38 or Ø50, using the supplied adapters, 
 Installing a bypass is mandatory and makes interventions on the appliance easier, 
 Adjust the water flow rate using valve VB, and keep valves VE and VS open, 
 check the tightening of the hydraulic connections, and for leaks. 
H04019‐00.A3.EN – 2013/01
ML1_Pac Alpha Ed 01-2013-noir.indd 14
5M 
kW 
0.98 
kW 
4.65 
4.45 
4.7 
dBA 
65.4 
dBA 
37.4 
 
7M 
230V‐50Hz 
1.56 
6.52 
7.09 
4.2 
66.7 
38.7 
16 
Fixing holes 
 
 
9M 
11M 
2.06 
2.6 
8.6 
10.5 
9.36 
12.4 
4.2 
4.1 
69 
72 
41 
44 
16/01/13 11:05