Possible settings

9.7 Switching the compensator on / off

Switching the compensator on / off
Possible settings

9.8 Calibration / adjustment of the vertical circle

The tool is correctly adjusted when supplied.
The values to which the tool is set may change over time or due to temperature fluctuations, transport or aging.
The tool therefore incorporates a feature that allows the settings to be checked and, if necessary, corrected by carrying
out an in-the-field re-calibration.
This is done by setting up the tool securely on a tripod of good quality and targeting an easily visible, clearly discernible
object within ±3 degrees of horizontal at a distance of approx. 70 – 120 m.

9.8.1 Starting the calibration procedure

The tool must be switched on before calibration can be started.
1.
Press and hold the R/L button and the Hold buttons simultaneously and then press the ON/OFF button.
2.
Wait until all characters appear in the display and then release the R/L and Hold buttons first.
1"
Display: dSP 1
5"
Display: dSP 5
10"
Display: dSP 10
ON
Display: TILT ON
OFF
Display: TILT OFF