Stop feature while refuelling during operation of AES models
In order to prevent unintended switching to gas
operation during refuelling, the electronic
system starts gas operation of the refrigerator
after the motor has been turned off for 15 minu-
tes. During this period the appliance is in ready
for operation mode ("stand-by"). In automatic
mode the "AU" indication only is illuminated.

5.2.4 Setting of cooling compartment temperature

F
G
(Fig. 22) Select the desired cooling compart-
ment temperature by pressing button B.
The LED display of the selected temperature
setting is illuminated.
The scale starts with MIN in the bottom LED
position (small crystal = highest temperature)
and climbs up to MAX in the upper LED positi-
on (big crystal = lowest temperature). Note: The
temperature levels do not relate to absolute
temperature values.

5.2.5 Additional features

The brightness of the display reduces after a
few seconds if no other buttons are pressed.
If the door is open, the interior lighting is swit-
ched off automatically after 2 minutes.
Failures are indicated by flashing of the failu-
re indicator LED.
B
Fig. 22
THE SIGN OF COMFORT
WARNING
The use of unshielded flames is prohibited
in petrol station environments
Should the refuelling stop last longer than
15 minutes, the refrigerator has to be swit-
ched off with button A or switched over to
another energy type.
The cooling unit's performance is influenced by
ambient temperatures. Please select the medi-
um setting for ambient temperatures between
+15°C and +25°C (refer to Fig. 22, temperature
level 3). The unit operates within its optimum
performance range.
Dometic refrigerators work according to the
absorption principle. For physical reasons, an
absorption system responds slowly to changes
made by the thermostat controller, by loss of
cooling energy through opening the door or
during storing food. The devices meet the coo-
ling performance requirements of the Climatic
Class SN acc. to EN/ISO 7371 in the temperatu-
re range of +10°C to +32°C ambient temperatu-
re.
For temperatures below +10°C, winter covers
should be installed. For ambient temperatures
exceeding +32°C for a longer period of time, it
is recommended installing Dometic additional
fan ( item no. 241 2985 - 00 ).
Only applicable with AES models
Should the door be kept open for too long
(more than 2 minutes), an acoustic signal is
initiated (pulsing whistle tone).
Should the electronic control detect any fai-
lure, an acoustic signal will sound (pulsing
whistle tone). At the same time the display starts
blinking ( for trouble-shooting, please refer to
section 5.12 ).