Tractel magfor II Série Notice D'utilisation page 24

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Determination of permanent magnet lifters magfor II capacity in case of S235 steel round
surface.
Please note, magfor II TP for thin plates are not designed for handling rounds.
Ø D min
magfor II 100
magfor II 100 HO
magfor II 200 HT
magfor II 300
magfor II 300 HO
magfor II 400 HT
magfor II 500
magfor II 500 HO
magfor II 800 HT
magfor II 1000
magfor II 1000 HO
magfor II 2000
magfor II 3000
magfor II 5000
* WLL: working load limit
* This value will be reduced if load characteristics (steel with low carbon content) and use
instructions of magnet (load horizontality, active poles condition, etc.) are not respected.
M 6053 M
rev 16 – 04/2021
GB
E
L
Ø D max
E min
(mm)
(mm)
(mm)
40
100
15
40
160
25
40
160
25
40
220
30
40
220
30
60
350
40
60
350
40
80
400
60
160
400
80
160
400
100 2 400 5 000 2 000 4 500 1 500 4 000
Ø
Air-gap
Air-gap
< 0,1 mm
0,1 to 0,3mm
WLL*
L max
WLL*
L max
(kg)
(mm)
(kg)
(mm)
50
2 500
40
1 700
80
3 500
65
3 000
125 3 500 100 3 000
170 4 000 140 3 500 110 3 000
215 4 000 180 3 500 140 3 000
360 4 500 300 4 000 240 3 500
450 4 500 380 4 000 300 3 500
800 5 000 650 4 500 550 4 000
1 200 5 000 1 000 4 500 750 4 000
Air-gap
0,3 to 0,5mm
WLL*
L max
(kg)
(mm)
30
1 500
50
2 500
80
2 500
Page 24/96
www.tractel.com

Publicité

Table des Matières
loading

Table des Matières