MAINTENANCE
Check Safety Valve
1.
Pull ring on safety valve (see Figure 6) and observe that
safety valve operates freely.
Figure 6 - Safety Valve
2.
If valve is stuck or does not operate smoothly, it must be
replaced with same type of valve.Take unit to authorized
service facility for repair.
Check Quick Connect Fittings and
Tank Drain Valves
1.
Push ON - OFF switch to OFF and unplug unit.
2.
Disconnect air tool or accessory from unit.
3.
Pull ring on safety valve to reduce air pressure. Release
safety valve ring.
WARNING
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.
• DO NOT direct air stream at self or others.
• Always wear ANSI Z87.1 approved safety glasses with side
shields.
4.
Open both drain valves (turn fully counterclockwise, see
Figure 3, earlier) and permit accumulated water to be
discharged.Valves should operate smoothly and have full
range of operation.
5.
After water has drained, close drain valves fully
clockwise.
NOTE: If drain valves are plugged, pull safety valve ring to
fully drain air from tank. Remove, clean and reinstall drain
valve.
12
Safety Valve Ring
Pressure Switch
Check / Change Pump Oil
Checking Oil Level
Use these steps to check oil level:
1.
Push ON - OFF switch to OFF and unplug unit.
2.
Place unit on a flat, level surface.
3.
Remove oil dipstick and wipe dipstick with clean cloth.
4.
Reinstall dipstick into oil fill opening.
5.
Carefully remove dipstick and verify that oil level is at
proper level (see Figure 7).
6.
If oil level is too low, add recommended oil to proper
level (see Figure 7). If oil is above MAXIMUM oil level,
remove excess oil, as described in next section.
Figure 7 - Oil Fill Information
7.
Reinstall oil dipstick.
Changing Oil
At recommended oil change interval, follow these steps:
1.
Push ON - OFF switch to OFF and unplug unit.
2.
Place unit on a flat, level surface.
WARNING
Operating air compressor and tubing are HOT
and can cause burns.
• DO NOT touch compressor or tubing.
• Allow compressor to cool before servicing.
3.
Remove oil dipstick and wipe dipstick with clean cloth.
4.
Position a suitable container under oil drain plug to
collect drain oil.
5.
Use an adjustable wrench to remove hex head drain plug.
Inset of
Dipstick
Oil Fill
Location
MAXIMUM
Oil Level
PROPER
Oil Level
Drain Plug

Publicité