rough framing
EN
3.3

minimum clearance to combustible enclosures

note:
Vent Sections
When passing through a wall, use fi restop spacer W010-1800 (supplied).
When passing through a ceiling, use fi restop spacer W500-0028 (not supplied).
1" [25mm] minimum all sides for vertical venting sections.
When passing through a ceiling, use firestop
W500-0028 (not supplied).
* The minimum enclosure
height is determined based
on volume of air needed in
the enclosure.
* 72"
(182.8cm)
min.
* Refer to "venting requirements" and "venting installation" sections.
** Clearances within the enclosure may be higher (refer to "minimum framing dimensions" section).
A
22
W415-2000 / D / 04.01.20
Insulated
sleeve
Non-combustible
material
12"
10 1/4"
[305mm]
EX36
59"
Combustible
Non-combustible
Brick
3"
[76mm]
to top
4"
min.
2"
[51mm] to
sides / bottom
Firestop
assembly
1" [25mm]
EX42
0" [0mm] if non-combustible
finishing material is used
such as brick and stone.
A
+ rise
63"