SPECIAL OR CRITICAL USERS INSTRUCTIONS
BREATHING AIR PRESSURE TABLE
This table lists Air pressure ranges needed to provide the RPB
that falls within the required range of 6 -15 cfm or 170 - 425 lts/min according to GOVERNMENT
REGULATIONS.
1. AIR
2. BREATHING
SOURCE
TUBE
ASSEMBLY
Portable
04-835/03-101
or
Constant Flow
Stationary
Valve Assembly
Compres-
sor
Set the air pressure at the point of attachment to the pressure setting specified in
column 6 for your breathing tube assembly, hose length and amount of hose sections.
Make sure the air is flowing through your apparatus when setting the pressure.
!WARNING! ALWAYS WEAR EAR PLUGS WHEN WEARING THIS APPARATUS.
RECOMMENDATION: Check that the air supply system can sufficiently supply every apparatus
connected to the system according to the user instructions.
!WARNING!
Make sure you understand the Breathing Air Pressure Table before using this respirator.
Determine your air source (column 1)
Find your breathing tube assembly (column 2)
Be sure your air supply hose is EN14594, AS/NZS 1715 approved
Z-LINK
breathing air hose.
®
Check your Z-LINK
AS/NZS 1715 approved length (column 4)
Set the air pressure at the point of attachment within the range specified (column 6)
for your breathing tube assembly, hose length and amount of hose sections.
Make sure air is flowing through your respirator when setting the pressure.
!WARNING! The Apparatus must be supplied with respirable air meeting the requirements
of EN12021, AS/NZS 1715 or Higher Quality.
3. AIR
4. SUPPLY
SUPPLY HOSE
HOSE LENGTH
(METERS)
04-312-25 (7.5m)
04-312-50 (15m)
04-312-100 (30m)
air supply hose is within the EN14594,
®
Z-LINK
®
®
5. MAX
NUMBER OF
SECTIONS
7.5
1
15
1
30
1
45
2
60
2
75
3
90
3
with the volume of air
6. PRESSURE
7. Flow Rate
RANGE (BAR)
l/m (at RPB)
0.65 - 0.75
272 - 310
0.77 - 0.87
268 - 298
0.97 - 1.07
235 - 257
1.17 - 1.27
222 - 238
1.45 - 1.60
221 - 240
1.70 - 1.85
224 - 243
1.90 - 2.05
222 - 238
9