Overview and device description
Fig. 1
System setup and installation
The system must be installed so that the front side is
accessible as the working and operator side; the dischar-
ge line is connected at the rear of the system. The sub-
strate on which the system is set up must be level, smoo-
th (e.g., screed) and firm. Material damage or cracks due
to unsuitable substrates are not covered by warranty.
The on-site connections for water drainage and power
connections must be specified by an installation techni-
cian and an electrician in accordance with the applicable
regulations of the location and the state of the art.
Translation of the original operating instructions
DN 50
Fig. 2
Connecting the water drain
After the device has been positioned, the supplied drain
(7) Fig. 1, 2 is connected to the on-site drainpipe. Height
of the on-site drain max. 100 mm
Note:
For higher drains, please also order wastewater pump 61
70 30 and connect it to the intended connection at the
rear of the system (centre of system rear panel, in the dis-
tribution box: The connection instructions for the waste
water pump can be found in the operating manual of the
pump.
Caution:
Unplug the power connector first!