Assembling the brush cleaning station
Fig. 7
- Place the station with the holes at the rear right of the
tank and fasten it from the rear of the system using the
two knurled screws (8) Fig. 7.
-
Operating the brush cleaning station
- The profiled surface is ideal for cleaning brushes.
- The brush comb and brush scrubber help to clean heavily
soiled and encrusted tools more easily.
-
Fitting the roller prewash tank
See figure 4. The tank with the mounting brackets (9) is
placed at an angle of about 20° diagonally on the moun-
ting spigots.
Function of the roller prewash tank
- Water is let into the prewash basin up to the upper edge
of the burl mat.
- By rolling the roller in the pre-wash basin, the roller is
pre-washed very easily and effectively, so that the main
wash cycle with the shower head or TurboWash is signi-
ficantly faster.
Installing the wastewater pump for
drains at higher levels
Fig. 8
The wastewater pump is necessary if the drain on-site is
at a higher level than the water outlet on the separating
plant.
Installation:
(8)
Attention:
Unplug the power plug first!
- Remove the catchment cages from the system.
- The siphon plug located in the outlet of the system
must be removed (by pulling/turning).
- Place the wastewater pump with the intake opening in
the drain and route the hose mounted on the pump out
of the system to the rear.
- Remove the drain pipe from the siphon and replace it
with the cap (check leak tightness).
- Connect the hose professionally to the drain provided
by the customer avoiding leaks.
- Connect the pump power cable to the mating part on
the rear of the separating system. For more information
on connecting the wastewater pump, please refer to
the pump operating instructions.
59
(13) Fig. 8
Translation of the original operating instructions