Electrical connection
Notice
Connection of the appliance to the
power supply must be carried out by a
specialised electrician.
When the machine is operated for the
Data
first time the
are to be checked and if necessary, set
correctly (see
tings
in the operating instructions).
Perform the electrical connection ac
cording to the regulations or provisions
made by the local electricity authority
and utility companies.
In rooms in which faultcurrent protec
tive switches are required or recom
mended in order to increase safety, the
release current must be 30 mA.
Use a faultcurrent protective switch
►
with the
symbol.
Approval for fixed connection, allpole
disconnectable by a main switch with
contact distance of min. 3 mm or plug
contact.
Time
and
settings
Settings / Menu Set-
Reduced mains power
The appliance may be changedover to
a reduced connection rate (see the fol
lowing electrical installation schemes).
Additional information regarding
changeover capabilities are located on
the sticker on the power cable of the
machine.
Notice
The switchover must be carried out by a
specialist elec tri cian.
For lower connected loads, the setting
►
Reduced mains power
adjusted accordingly.
Warning
Risk of electric shock and risk of fire!
No extension cables, no multicoupling
and no plugin, mobile time switches
may be used.
L1 brown
L2 black
needs to be
N
blue
PE yellow-green
EN 53